Confort thermique et qualité de l'air intérieur dans des pièces équipées de ventilation personnalisée intégrée et de systèmes de distribution d'air sous le plancher.
Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems.
Auteurs : LI R., SEKHAR S. C., MELIKOV A. K.
Type d'article : Article
Résumé
A comprehensive study comprising physical measurements and human subject experiments was conducted to explore the potential for improving occupants’ thermal comfort and indoor air quality (IAQ) using a personalized ventilation (PV) system combined with an under-floor air distribution(UFAD) system. The integrated PV-UFAD system, when operated at relatively high temperature of the air supplied from the UFAD system, provided comfortable cooling of the facial region, improved inhaled air quality, and decreased the risk of “cold feet,” which is often reported in rooms with UFAD alone. This article explores associations between the physical measurements and human responses in a room served with a PV-UFAD system. The experiments were conducted in a field environmental chamber served by two dedicated systems: a primary air-handling unit (AHU) for 100% outdoor air that is supplied through the PV air terminal devices and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Velocity and temperature distribution in the chamber were measured. A breathing thermal manikin was used to measure the heat loss from 26 body segments and to determine the equivalent temperature. The responses of 30 human subjects were collected. The experiments were performed at various combinations of room air and PV air temperatures. The results reveal improved overall thermal sensation and decrease of cold feet complaints, as well as improved inhaled air quality (including perceived air quality) with PV-UFAD in comparison with the reference case of UFAD alone or mixing ventilation with a ceiling supply diffuser. Increase of predicted draft rating with the decrease of the local thermal sensation at the feet was identified. The manikin-based equivalent temperature determined for the face was positively correlated with thermal sensation at the face region. The measured inhaled air quality indices (personalized exposure effectiveness and personalized exposure index) were improved by decreasing PV supply air temperature. The perceived inhaled air freshness increased with the decrease of the inhaled air temperature and increase of facial velocity.
Détails
- Titre original : Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems.
- Identifiant de la fiche : 30003258
- Langues : Anglais
- Source : HVAC&R Research - vol. 17 - n. 5
- Date d'édition : 10/2011
- DOI : http://dx.doi.org/10.1080/10789669.2011.544834
Liens
- Liens externes :
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
-
Kvalita vzduchu a tepelná pohoda pri podlahovém...
- Auteurs : CERMÁK R., MELIKOV A. K.
- Date : 2005
- Langues : Tchèque
- Source : Vytápení Vetrání Instalace - vol. 14 - n. 5
Voir la fiche
-
Transmission of exhaled air between occupants i...
- Auteurs : CERMAK R., MELIKOV A. K.
- Date : 05/09/2004
- Langues : Anglais
Voir la fiche
-
Thermal environment with underfloor air conditi...
- Auteurs : YOKOYAMA K., INOUE T.
- Date : 04/09/1991
- Langues : Anglais
Voir la fiche
-
Experimental study including subjective evaluat...
- Auteurs : KRAJCÍK M., TOMASI R., SIMONE A., et al.
- Date : 11/2013
- Langues : Anglais
- Source : HVAC&R Research - vol. 19 - n. 8
Voir la fiche
-
Numerical study of the effect of air terminal l...
- Auteurs : YAO T., LIN Z.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche