Document IIF
Conservation de l'énergie d'un système de conditionnement d'air split d'une puissance de 1 TR (ou 3,5 kW) utilisant le refroidissement évaporatif.
Energy conservation on 1 TR split air conditioner using evaporative cooling.
Auteurs : POKHRIYAL M., NARYANKHEDKAR K. G., ATREY M. D.
Résumé
The paper presents design and development of an energy efficient 1 TR split air conditioner based on evaporative cooling. The evaporative cooling is the most desirable method to design an energy efficient unit since the heat transfer involves water as coolant. However, very few researchers have applied this technique for small capacity units. The objective of this work is to improve COP of the unit by operating it at lower condensing temperature which helps in reduction of compressor power. The rotary compressor selected for this work consumes 1.25 kW as per manufacturer's specifications for a standard one TR split air conditioner unit, giving a COP of 2.8. With this compressor and one TR air conditioner, using evaporative cooling the COP has been experimentally evaluated to be 4.11. This paper highlights details of this work. It gives in detail, the design of condenser coil, cooling tower and capillary tube made specifically for this purpose. It also compares the experimental results with the predictions based on the design model developed for this purpose. The study is further extended to evaluate the effect of various design parameters on the performance of the cooler.
Documents disponibles
Format PDF
Pages : ICR07-E1-352
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy conservation on 1 TR split air conditioner using evaporative cooling.
- Identifiant de la fiche : 2008-0803
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
-
Dossier climatisation.
- Auteurs : LANCIEUX C., RAKETAMANGA P. Y., VRINAT G., et al.
- Date : 03/2005
- Langues : Français
- Source : Rev. gén. Froid - vol. 95 - n. 1051
Voir la fiche
-
Use of condensate drain to pre-cool the inlet a...
- Auteurs : SAWAN R., GHALI K., HINDI M. al-
- Date : 06/2012
- Langues : Anglais
- Source : HVAC&R Research - vol. 18 - n. 3
Voir la fiche
-
Experimental study on the flow resistance of in...
- Auteurs : SUN T., TANG T., MA J., YAN Y., FU T., ZHANG H., LI J., LI W., SHEN H., HUAN C.
- Date : 04/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 160
- Formats : PDF
Voir la fiche
-
Reduction of energy consumption in air-conditio...
- Auteurs : NDUKAIFE T. A., AGWU NNANNA A. G.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Choix de construction optimale pour un échangeu...
- Auteurs : GARANOV S. A., PANTELEEV D. A., SOKOLIK A. N.
- Date : 10/2015
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 10
Voir la fiche