Considérations relatives à l'utilisation de glace binaire pour les conditionneurs d'air destinés au confort.
Aspects concerning the use of binary ice for comfort air-conditioners.
Numéro : pap. n. 140
Auteurs : NICHITA M. T., DUMITRESCU R., CHIRIAC F.
Résumé
This paper refers to the use of ice-slurry, as an intermediary phase-changing cooling fluid, in air-conditioning. Ice-slurry is provided by a scraper-type generator that is part of a single stage compression system working with R404A, as primary refrigerant. A mixture of ice slurry, water, and talin (10% mass concentration) represents the secondary cooling medium. This was used in a heat exchanger of classical type, namely an air cooler, with aluminum fins, of 0.1 mm thickness. This paper reports experimental results of ice-slurry used as cooling fluid for air-conditioning consumers of various cooling capacity demands. Experiments have been carried out using two different ice mass fractions, namely approximately15% and 20% and two different air volumetric flow rates, namely Qair = 3000 m3 / h and Qair = 2000 m3 / h The cooling capacity of the ice-slurry generator has been experimentally validated by simultaneously determining the thermal capacity for the evaporator (as a function power input to the compressor), for the air-cooler and air heaters.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Aspects concerning the use of binary ice for comfort air-conditioners.
- Identifiant de la fiche : 30008674
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
-
Techniczne i ekonomiczne aspekty stosowania zaw...
- Auteurs : NIEZGODA-ZELASKO B., ZALEWSKI W.
- Date : 15/10/2008
- Langues : Polonais
- Source : Projektowanie i eksploatacja przyjaznych srodowisku systemów chlodniczych i klimatyzacyjnych. Miedzynarodowa konferencja. XL Dni chlodnictwa.
- Formats : PDF
Voir la fiche
-
Reception of binary ice in the ice generator of...
- Auteurs : ZIMIN A. V., KHMELNIUK M., MINENKOV V.
- Date : 02/09/2013
- Langues : Anglais
- Source : Compressors 2013: 8th International Conference on Compressors and Coolants.
- Formats : PDF
Voir la fiche
-
Particle size distribution in ice slurry system...
- Auteurs : KOFFLER M., SCHAAF J., KAUFFELD M.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Study on generator for ice slurry using the pre...
- Auteurs : FUMOTO K., KAWANAMI T., INAMURA T.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Ice slurry as secondary coolant in air coolers....
- Auteurs : DIZ R., FERNÁNDEZ-SEARA J., PARDIÑAS A. A.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche