Corrélation du transfert de chaleur et corrélation du facteur de frottement pour un conduit rendu rugueux artificiellement grâce à un enrobage rugueux et des nervures métalliques.
Heat transfer and friction factor correlation for artificially roughened duct with metal grit ribs.
Auteurs : KARMARE S. V., TIKEKAR A. N.
Type d'article : Article
Résumé
This paper presents the results of an experimental investigation of heat transfer to the airflow in the rectangular duct of an aspect ratio 10:1. The top wall surface is made rough with metal ribs of circular cross section in staggered manner to form defined grid. The roughened wall is uniformly heated and the other walls are insulated. This geometry of duct closely corresponds to that used in solar air heaters. The effect of grit geometry [i.e., relative roughness height of grid (e/Dh), relative roughness pitch of grit (p/e), relative length of grit (l/s)] on the heat transfer coefficient and friction factor is investigated. The range of variation of system parameters and operating parameters is investigated within the limits, as e/Dh: 0.035 to 0.044, p/e: 12.5-36 and l/s: 1.72-1, against variation of Reynolds number: 4000-17,000. It is observed that the plate of roughness parameters l/s= 1.72, e/Dh= 0.044, p/e= 17.5 shows optimum performance. Correlations for Nusselt number and friction factor in terms of above parameters are developed which reasonably correlate the experimental data. [Reprinted with permission from Elsevier. Copyright, 2007].
Détails
- Titre original : Heat transfer and friction factor correlation for artificially roughened duct with metal grit ribs.
- Identifiant de la fiche : 2008-0541
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 50 - n. 21-22
- Date d'édition : 10/2007
Liens
Voir d'autres articles du même numéro (2)
Voir la source
Indexation
-
Forced convection and flow friction characteris...
- Auteurs : LUO D. D., LEUNG C. W., CHAN T. L.
- Date : 12/2004
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 47 - n. 25
Voir la fiche
-
The influence of Reynolds number and size effec...
- Auteurs : KOCH P.
- Date : 2006
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 27 - n. 4
Voir la fiche
-
Pressure loss coefficient measurements of two c...
- Auteurs : MYLARAM N. K., IDEM S.
- Date : 01/2005
- Langues : Anglais
- Source : HVAC&R Research - vol. 11 - n. 1
Voir la fiche
-
Numerical and experimental study on heat transf...
- Auteurs : FAN X., WANG Y., ZHENG H., et al.
- Date : 21/07/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Heat transfer and pressure drop in rectangular ...
- Auteurs : CHANG S. W., LIOU T. M., CHIANG K. F., et al.
- Date : 02/2008
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 51 - n. 3-4
Voir la fiche