Document IIF
Corrélation expérimentale du transfert de chaleur du HFC-134a sur les tubes à surface améliorée : le «Turbo-E».
Experimental correlation of pool boiling heat transfer for HFC-134a on enhanced tubes: Turbo-E.
Auteurs : YANG S. W., JEONG J., KANG Y. T.
Type d'article : Article, Article de la RIF
Résumé
The objectives of this paper are to study the heat transfer characteristics for enhanced surface tubes in the pool boiling and to provide a guideline for the design conditions for the evaporator using HFC-134a. The shape of tube surfaces, the wall superheat, and the saturation temperature are considered as the key parameters. Copper tubes are treated with different helix angles and the saturation temperatures are controlled from 3 to 16°C. It is found that the pool boiling heat transfer coefficient decreases with increasing the wall superheat. It is also found that boiling heat transfer coefficients for Turbo-II and Turbo-III are 1.5-3.0 and 1.2-2.0 times higher than that for Turbo-I without the helix angle, respectively. The higher heat transfer performance from Turbo-II and Turbo-III can be explained by the ''bubble detention'' phenomenon on the surface without the helix angle for the Turbo-I. The experimental correlations for the pool boiling heat transfer on the present enhanced tubes without (Type I) and with the helix angle (Type II and Type III) are developed with the error bands of plus or minus 30%, respectively.
Documents disponibles
Format PDF
Pages : 130-137
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental correlation of pool boiling heat transfer for HFC-134a on enhanced tubes: Turbo-E.
- Identifiant de la fiche : 2008-0604
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 1
- Date d'édition : 01/2008
Liens
Voir d'autres articles du même numéro (16)
Voir la source
-
Average heat transfer coefficient for pool boil...
- Auteurs : GORGY E., ECKELS S.
- Date : 09/2010
- Langues : Anglais
- Source : HVAC&R Research - vol. 16 - n. 5
Voir la fiche
-
Condensation enhancement of R22 by twisted-tape...
- Auteurs : KUMAR R., AGARWAL K. N., LAL S. N.
- Date : 2005
- Langues : Anglais
- Source : ASHRAE Transactions. 2005 Winter Meeting. Volume 111, part 1 + CD-ROM.
Voir la fiche
-
Predicting flow boiling heat transfer for refri...
- Auteurs : KANDLIKAR S. G., RAYKOFF T.
- Date : 29/05/1996
- Langues : Anglais
- Source : Proceedings of the 2nd European Thermal-Sciences (EUROTHERM) and 14th UIT National Heat Transfer Conference 1996.
Voir la fiche
-
Etude expérimentale sur le coefficient de trans...
- Auteurs : SHANG P.
- Date : 11/2008
- Langues : Chinois
- Source : HV & AC - vol. 38 - n. 217
- Formats : PDF
Voir la fiche
-
An investigation of condensation heat transfer ...
- Auteurs : XIE T., ECKELS S. J.
- Date : 01/2003
- Langues : Anglais
- Source : HVAC&R Research - vol. 9 - n. 1
Voir la fiche