Document IIF
Corrélation générale pour les flux massiques de frigorigènes en écoulement à l'intérieur de tubes capillaires adiabatiques (+ erratum).
A generalized correlation for refrigerant mass flow rate through adiabatic capillary tubes (+ erratum).
Résumé
A capillary tube is a common expansion device used in small refrigeration and air-conditioning systems. A generalized correlation for refrigerant flow rate in adiabatic capillary tubes is developed by implementing dimensionless parameters based on extensive experimental data for R22, R290, and R407C measured in this study. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of tube inlet conditions, capillary tube geometry, and refrigerant properties on mass flow rate. The generalized correlation yields good agreement with the present data for R22, R290, and R407C with average and standard deviations of 0.9 and 5.0%, respectively. Approximately 97% of the present data are correlated within a relative deviation of ±10%. Further assessments of the correlation are made by comparing the predictions with measured data for R12, R134a, R152a, R410A, and R600a in the open literature. The correlation predicts the data for those five refrigerants with average and standard deviations of -0.73 and 6.16%, respectively.
Documents disponibles
Format PDF
Pages : 881-888
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A generalized correlation for refrigerant mass flow rate through adiabatic capillary tubes (+ erratum).
- Identifiant de la fiche : 2004-0834
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 26 - n. 8
- Date d'édition : 12/2003
Liens
Voir d'autres articles du même numéro (9)
Voir la source
-
REGULATION ET COMPENSATION DANS LES REFRIGERATE...
- Auteurs : ROBIN M.
- Date : 1987
- Langues : Français
- Source : Rev. gén. Froid - vol. 77 - n. 1
Voir la fiche
-
DETERMINATION OF OPTIMUM REFRIGERANT CHARGE FOR...
- Auteurs : DMITRIYEV V. I., PISARENKO V. E.
- Date : 1984
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 7 - n. 3
- Formats : PDF
Voir la fiche
-
Diabatycznosc procesu dlawienia dobór geometrii...
- Auteurs : FLOREK R., KRÓLICKI Z.
- Date : 2004
- Langues : Polonais
- Source : Chlodnictwo - vol. 39 - n. 1-2
Voir la fiche
-
DETERMINATION DU DIAMETRE D'UN RESTRICTEUR POUR...
- Auteurs : KROLICKI Z., MACZEK K.
- Date : 1981
- Langues : Polonais
- Source : Chlodnictwo - vol. 16 - n. 9-10
Voir la fiche
-
Performance evaluation of household refrigerato...
- Auteurs : ESPINDOLA R. S., KNABBEN F. T., MELO C., HERMES C. J. L.
- Date : 03/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 111
- Formats : PDF
Voir la fiche