Document IIF
Corrélation générale pour les flux massiques de frigorigènes en écoulement à l'intérieur de tubes capillaires adiabatiques (+ erratum).
A generalized correlation for refrigerant mass flow rate through adiabatic capillary tubes (+ erratum).
Résumé
A capillary tube is a common expansion device used in small refrigeration and air-conditioning systems. A generalized correlation for refrigerant flow rate in adiabatic capillary tubes is developed by implementing dimensionless parameters based on extensive experimental data for R22, R290, and R407C measured in this study. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of tube inlet conditions, capillary tube geometry, and refrigerant properties on mass flow rate. The generalized correlation yields good agreement with the present data for R22, R290, and R407C with average and standard deviations of 0.9 and 5.0%, respectively. Approximately 97% of the present data are correlated within a relative deviation of ±10%. Further assessments of the correlation are made by comparing the predictions with measured data for R12, R134a, R152a, R410A, and R600a in the open literature. The correlation predicts the data for those five refrigerants with average and standard deviations of -0.73 and 6.16%, respectively.
Documents disponibles
Format PDF
Pages : 881-888
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A generalized correlation for refrigerant mass flow rate through adiabatic capillary tubes (+ erratum).
- Identifiant de la fiche : 2004-0834
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 26 - n. 8
- Date d'édition : 12/2003
Liens
Voir d'autres articles du même numéro (9)
Voir la source
-
Design parametric study of a lateral configured...
- Auteurs : DUBBA S. K., KUMAR R.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
PERFORMANCE EVALUATION OF PURE AND MIXED REFRIG...
- Auteurs : JUNG D. S., RADERMACHER R.
- Date : 17/07/1990
- Langues : Anglais
Voir la fiche
-
The experimental study on refrigerant mixture a...
- Auteurs : HUA X. L., CHEN W., YIN G. W.
- Date : 14/07/1992
- Langues : Anglais
Voir la fiche
-
A generalized correlation for the characteristi...
- Auteurs : YANG L., WANG W.
- Date : 03/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 2
- Formats : PDF
Voir la fiche
-
Numerical simulation of capillary tubes. Applic...
- Auteurs : ABLANQUE N., RIGOLA J., PÉREZ-SEGARRA C. D., et al.
- Date : 12/07/2010
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF