Cryoréfrigérateur constitué d'un tube à pulsation haute fréquence à deux étages délivrant une température nominale inférieure à 20 K.
High frequency two-stage pulse tube cryocooler with base temperature below 20 K.
Auteurs : YANG L. W., THUMMES G.
Type d'article : Article
Résumé
This paper reports on the design and test of a two-stage pulse tube cooler which is driven by a linear compressor with nominal input power of 200 W at an operating frequency of 30-45 Hz. A parallel configuration of the two pulse tubes is used with the warm ends of the pulse tubes located at ambient temperature. For both stages, the regenerator matrix consists of a stack of stainless steel screen. At an operating frequency of 35 Hz and with the first stage at 73 K a lowest stationary temperature of 19.6 K has been achieved at the second stage. The effects of input power, frequency, average pressure, and cold head orientation on the cooling performance are also reported. An even lower no-load temperature can be expected from the use of lead or other regenerator materials of high heat capacity in the second stage.
Détails
- Titre original : High frequency two-stage pulse tube cryocooler with base temperature below 20 K.
- Identifiant de la fiche : 2005-2390
- Langues : Anglais
- Source : Cryogenics - vol. 45 - n. 2
- Date d'édition : 02/2005
Liens
Voir d'autres articles du même numéro (3)
Voir la source
Indexation
-
Tube à gaz pulsé.
- Auteurs : DOMBLIDES J. P., et al.
- Date : 01/1992
- Langues : Français
- Source : Rev. gén. Froid - vol. 82 - n. 1
Voir la fiche
-
Nouvelle configuration d'un réfrigérateur à tub...
- Auteurs : GAO J. L., MATSUBARA Y.
- Date : 1994
- Langues : Japonais
- Source : Cryogenics/ Cryog. Eng. - vol. 29 - n. 4
Voir la fiche
-
Optimum phase angle between pressure and gas di...
- Auteurs : KASUYA M., YUYAMA J., GENG Q., GOTO E.
- Date : 1992
- Langues : Anglais
- Source : Cryogenics - vol. 32 - n. 3
Voir la fiche
-
Multistage pulse tubes.
- Auteurs : WAELE A. T. A. M. de, TANAEVA I. A., JU Y. L.
- Date : 07/2000
- Langues : Anglais
- Source : Cryogenics - vol. 40 - n. 7
Voir la fiche
-
Novel configuration of three-stage pulse tube r...
- Auteurs : MATSUBARA Y., GAO J. L.
- Date : 04/1994
- Langues : Anglais
- Source : Cryogenics - vol. 34 - n. 4
Voir la fiche