Des frigorigènes au PRP inférieur à celui du R404A dans les compresseurs de type économiseurs.
Lower GWP refrigerants compared to R404A for economizer style compressors.
Numéro : pap. 1390
Auteurs : SJOHOLM L., KLEINBOEHL C., MA Y. C.
Résumé
Two economizer style compressors are explored, where the high pressure liquid is sub-cooled with a heat exchanger, while the evaporation side in the heat exchanger is connected to an intermediate compressor port. The intermediate port has a higher pressure than the suction pressure and a lower pressure than the discharge pressure. The two compressors being studied are of the scroll and screw type. One of the compressors is an open shaft compressor and the other one is a hermetic compressor. Both compressors have been modeled based on test data with R404A and at conditions that correspond to TRU (Transport Refrigeration Unit) applications. The compressor models have been used to explore lower GWP refrigerants such as R407A, R407F, N-40a, DR7 and DR33. For both compressors, each alternative refrigerant is compared against the baseline refrigerant R404A. This paper examines discharge temperature, capacity and "capacity/input power" (or COP, coefficient of performance) relative to the R404A baseline.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Lower GWP refrigerants compared to R404A for economizer style compressors.
- Identifiant de la fiche : 30014112
- Langues : Anglais
- Source : 2014 Purdue Conferences. 22nd International Compressor Engineering Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (138)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Compresseurs;
HFC - Mots-clés : R410A; Substitut; Simulation; Performance; GWP; Frigorigène; Compresseur à vis; Compresseur à spirale; Compresseur
-
Utilisation du R134a dans les compresseurs rota...
- Auteurs : SIMONIN D.
- Date : 08/12/1992
- Langues : Français
Voir la fiche
-
Steady state and transient validation of heat p...
- Auteurs : BHANOT V., BACELLAR D., LING J., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Performance evaluation of scroll compressor for...
- Auteurs : SAWAI K., YAMAMOTO S., HASE S., KOHAYAKAWA T., MORIMOTO T., ASHITANI M.
- Date : 16/08/1997
- Langues : Anglais
- Source : Proceedings of the '97 International Compressor Technique Conference.
Voir la fiche
-
Evaluating compressor performance with low-GWP ...
- Auteurs : WADA E., LYU T., TOJO K., IKUMI Y., NAKAMURA H., SAITO K.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 25th International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Modeling of R-410A variable capacity compressor...
- Auteurs : GALL J., FISHER D. E., CORTI G., et al.
- Date : 10/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 58
- Formats : PDF
Voir la fiche