Destruction des chlorofluorocarbures et recyclage des réfrigérateurs domestiques électriques usagés.

[In Japanese. / En japonais.]

Auteurs : SAITO H.

Type d'article : Article

Résumé

Per appliance it is estimated that about 150 grams of CFC-12 are contained in the refrigerating cycle and about 600 grams of CFC-11 in the foam. About 80% (at an ambient temperature of 20°C) of CFC-12 is dissolved in refrigerating machine oil. It is necessary to pulverize insulation and recover CFC-11 from the fine foams in this insulation. CFC-11 that is degassed in the shredder must be recovered with an absorption unit to achieve a high recovery rate. CFCs, which bond together firmly and are stable, require a temperature of at least 800°C for destruction. Since a few years ago, destruction of CFCs has received practical application with a few exceptions.

Détails

  • Titre original : [In Japanese. / En japonais.]
  • Identifiant de la fiche : 2000-0193
  • Langues : Japonais
  • Source : Refrigeration - vol. 73 - n. 849
  • Date d'édition : 07/1998
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.