Détecteurs de monoxyde de carbone dans les résidences : où les mettre ?

Siting of domestic carbon monoxide detectors.

Auteurs : ROSS D. I.

Résumé

Both experimental investigations and computational modeling (using CFD and multi-zonal codes) were performed to investigate the distribution of CO in the home. The study showed that as the CO emission is initially hot, a buoyant plume will rise to the ceiling. Consequently, a vertical CO concentration gradient is established in the room. This gradient diminishes as the flow spreads through the home. Using data from the study, details of CO poisoning incidents and additional experiments on the audibility of the detectors, a set of siting recommendations was produced.

Détails

  • Titre original : Siting of domestic carbon monoxide detectors.
  • Identifiant de la fiche : 2002-0310
  • Langues : Anglais
  • Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
  • Date d'édition : 09/07/2000
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (67)