Détériorations du transfert de chaleur et de masse dans une banque de tubes à membranes fibreuses elliptiques creuses pour la déshumidification de l'air par déshydratant liquide.
Heat and mass transfer deteriorations in an elliptical hollow fiber membrane tube bank for liquid desiccant air dehumidification.
Auteurs : HUANG S. M., QIN F. G. F., YANG M., et al.
Type d'article : Article
Résumé
A hollow fiber membrane tube bank (HFMTB) is commonly used for liquid desiccant air dehumidification to prevent small liquid desiccant droplets from escaping to the processing air. Due to the extrusions during the fabrication process, cross-sectional shapes of the circular hollow fibers are easily changed to elliptical ones. To know the effects of the shape changes of the
fibers, the conjugate heat and mass transfer in an elliptical hollow fiber membrane tube bank (EHFMTB) employed for liquid desiccant air dehumidification is investigated. The liquid desiccant flows inside the fibers, while the air flows in the shell side in a counter flow arrangement. In the tube bank, a typical unit cell consisting of a single fiber, the desiccant flowing inside the fiber and the air stream flowing outside the fiber, is considered. The airstream outside the fiber has an outer free surface. The equations governing the fluid flow and heat mass transfer in the two streams are solved together with the conjugate heat and mass transfer boundary conditions. The local and average Nusselt and Sherwood numbers in the unit cell are then obtained and experimentally validated. It is found that heat and mass transfer are substantially deteriorated in the EHFMTB.
Détails
- Titre original : Heat and mass transfer deteriorations in an elliptical hollow fiber membrane tube bank for liquid desiccant air dehumidification.
- Identifiant de la fiche : 30007602
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 57 - n. 1-2
- Date d'édition : 08/2013
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2013.04.004
Liens
Voir d'autres articles du même numéro (5)
Voir la source
-
A preliminary experimental study on the perform...
- Auteurs : WARNER J., LIU X., QU M., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental performance of a liquid desiccant ...
- Auteurs : DAS R. S., TRIPATHI S., JAIN S.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Experimental and theoretical analysis of liquid...
- Auteurs : CHEN Y., ZHANG X., YIN Y.
- Date : 05/04/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
Voir la fiche
-
Expérience sur le coefficient de transfert de m...
- Auteurs : GAO Y., ZHANG H., YOU S., et al.
- Date : 01/2012
- Langues : Chinois
- Source : HV & AC - vol. 42 - n. 259
- Formats : PDF
Voir la fiche
-
Heat compensation method for evaluating heat an...
- Auteurs : ZHANG X., CAO R., YIN Y., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche