Développement d’un support de charge de compresseur commercial léger pour mesurer la performance d’un compresseur fonctionnant avec des frigorigènes à faible GWP.

Development of a light-commercial compressor load stand to measure compressor performance using low-GWP refrigerants.

Numéro : pap. 1455

Auteurs : SCHMIDT D., SINGLETON J., BRADSHAW C. R.

Résumé

Popular hydrofluorocarbon refrigerants such as R134a and R410A are in the process of being phased out due to the high Global Warming Potential (GWP) of these fluids. A large variety of low-GWP refrigerants are being considered as replacements including R1234yf, R1234ze(E), R1234ze(D), R32, and blends of these with traditional refrigerants. As a result of high efficiency standards for HVAC&R equipment, the choice of refrigerant has a large impact on the design of a compressor to maximize its efficiency. Therefore, changing the most common refrigerants will require significant design changes to compressors and test environments that support re-design activities such as a hot-gas bypass compressor load stand. The hot-gas bypass style is a common system design to test compressors and is used for its many benefits, including rapid movement between testing conditions and low operational cost. A thermodynamic model of a hot-gas bypass cycle has been developed in Engineering Equation Solver (EES). Outputs from this model were used to select the components and piping sizes in combination with ASHRAE guidelines. The design capacity for the load stand is a range of 10-80 tons (35-281 kW), compressor capacity. The large range in capacities desired created many design challenges to overcome including maintaining proper oil circulation and refrigerant velocity. Once constructed, the compressor load stand will be capable of testing the performance of different compressors over a range of operating conditions. It will also have independent control over oil circulation/injection rate as well as a dedicated economizer circuit. These capabilities can then be used to optimize a wide spectrum of compressor types on low-GWP refrigerants. Ultimately, the load stand will serve as a new addition to the thermal systems research infrastructure at Oklahoma State University. This will allow for the continuation of research into new compressor technologies, as well as, for improvements in compressor efficiency in existing technologies.

Documents disponibles

Format PDF

Pages : 10

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Development of a light-commercial compressor load stand to measure compressor performance using low-GWP refrigerants.
  • Identifiant de la fiche : 30024359
  • Langues : Anglais
  • Source : 2018 Purdue Conferences. 24th International Compressor Engineering Conference at Purdue.
  • Date d'édition : 09/07/2018

Liens


Voir d'autres communications du même compte rendu (130)
Voir le compte rendu de la conférence