Recommandé par l'IIF
Développement et évaluation expérimentale d’une méthode d’essai de charge automatique pour les réfrigérateurs ménagers.
Development and experimental evaluation of an automated charge testing methodology for domestic refrigerators.
Numéro : 2481
Auteurs : LIANG C., KURTULUS O., ZIVIANI D., GROLL E. A., BRAUN J. E.
Résumé
Optimizing the refrigerant charge in a vapor compression cycle can lead to improvements in system performance and energy savings. Manufacturers often perform extensive experimental charge testing under different operating conditions to determine the optimal system charge of a certain product. However, the current de-facto industry standard procedure for performing such evaluation involves repeated charging and evacuating of equipment which is a time-consuming effort. In this work, an automated charge testing device and method were developed to perform a charge optimization for domestic refrigerators with the unit operating. This device consists of a combination of three solenoids to isolate a small calibrated volume of liquid refrigerant. This calibrated volume is typically around 2cc and allows a very small amount of refrigerant, usually less than 5 grams based on the density of liquid, to be charged into a unit with consistent accuracy and repeatability. This work also includes the development of a methodology for utilizing the device including software that automatically operates the device to charge the unit with additional refrigerant, collects and compares performance data, and detects when the optimal charge is reached to end the experiment. With the developed methodology, the entire procedure can be performed without human interaction saving a great amount of time and effort compared to conventional charge testing methods.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Development and experimental evaluation of an automated charge testing methodology for domestic refrigerators.
- Identifiant de la fiche : 30028490
- Langues : Anglais
- Sujet : Technologie
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 05/2021
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (184)
Voir le compte rendu de la conférence
-
Refrigerant charge optimization in household re...
- Auteurs : MELO C.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
A capillary tube: refrigerant charge design met...
- Auteurs : BOENG J., MELO C.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
An innovative charge optimization process for c...
- Auteurs : BOENG J., MELO C.
- Date : 10/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Formats : PDF
Voir la fiche
-
Optimal design of a light commercial freezer th...
- Auteurs : PISANO A., MARTÍNEZ-BALLESTER S., CORBERÁN J. M., et al.
- Date : 04/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 52
- Formats : PDF
Voir la fiche
-
Testing the safety of domestic refrigerators wi...
- Auteurs : GIGIEL A.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche