DISPOSITIF CAPILLAIRE ENFERME POUR LE MANIEMENT A FAIBLE PESANTEUR DE L'HELIUM II.

ENCLOSED CAPILLARY DEVICE FOR LOW GRAVITY MANAGEMENT OF HELIUM II.

Auteurs : FRANK D. J., YUAN S. W. K.

Type d'article : Article

Résumé

CET ARTICLE DECRIT ET ANALYSE UN DISPOSITIF DE GALERIE ENFERMEE CONCU POUR RECUEILLIR DE L'HELIUM II ET L'ENVOYER DANS UNE POMPE. CE DISPOSITIF PERMET A LA PLUS GRANDE PARTIE DU LIQUIDE DE SE DEPLACER DANS LE RESERVOIR TANDIS QU'IL MAINTIENT UN ECOULEMENT DE LIQUIDE VERS LA POMPE. SEUL LE LIQUIDE DES CANAUX DE LA GALERIE RECOUVERTS D'ECRANS ET DES RESERVOIRS SUPERIEURS ET INFERIEURS EST ENFERME. LE DISPOSITIF FONCTIONNE EN FOURNISSANT DES PASSAGES DE LIQUIDE DOMINES PAR LA TENSION SUPERFICIELLE PROVENANT DE TOUS LES EMPLACEMENTS DU RESERVOIR VERS LE RESERVOIR INFERIEUR QUI ABRITE LA POMPE. LA PRESSION DU FLUIDE DANS LES CANAUX POUVANT ETRE INFERIEURE A LA PRESSION DE VAPEUR SATUREE, ON ANALYSE LA CAVITATION DE L'HELIUM II POUR DETERMINER S'IL PEUT Y AVOIR CAVITATION.

Détails

  • Titre original : ENCLOSED CAPILLARY DEVICE FOR LOW GRAVITY MANAGEMENT OF HELIUM II.
  • Identifiant de la fiche : 1988-2202
  • Langues : Anglais
  • Source : Cryogenics - vol. 28 - n. 2
  • Date d'édition : 1988

Liens


Voir d'autres articles du même numéro (9)
Voir la source