Résumé
Multiple-split air conditioning (MSAC) system has become an attractive form of air-conditioning system for small-sized commercial and residential buildings. For a common room air conditioner, the only factor affecting the performance under a fixed outdoor and indoor condition is load rate of the indoor unit. But for the MSAC system, the indoor units will have quite different working situations under the same system load rate. It has been found that when the indoor and outdoor conditions (temperature and relative humidity) keep constant, the system COP will be within a “performance domain” related to the system load rate and the indoor load unevenness index. In this paper, the part load performances of MSAC systems are studied. As a result, it is found that whether the conditions changed, the performance domain will always exist. Through further analysis, it is pointed out that the shape of performance domain is related to the conditions, and the quantitative results are presented. This study is a theoretical foundation of design optimization, energy consumption prediction and evaluation in MSAC systems.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance domain of multiple-split air conditioning system.
- Identifiant de la fiche : 30000772
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 12/07/2010
Liens
Voir d'autres communications du même compte rendu (121)
Voir le compte rendu de la conférence
-
A comparative study on the performance and envi...
- Auteurs : CHEN W.
- Date : 01/2008
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 28 - n. 1
Voir la fiche
-
Thermoeconomic analysis and optimization of res...
- Auteurs : BARREIRA E. M., NEGRÃO C. O. R., HERMES C. J. L.
- Date : 01/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 50 - n. 1
Voir la fiche
-
Experimental study of residential air-to-air he...
- Auteurs : TRAN C. T., RIVIÈRE P., MARCHIO D., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Système de sous-refroidissement avec des systèm...
- Auteurs : ISHII S., KAWAKAMI Y., TANINO M.
- Date : 07/2008
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 136
Voir la fiche
-
Experimental evaluation of reversible CO2 resid...
- Auteurs : JAKOBSEN A., SKIPLE T., NEKSÅ P., et al.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche