Document IIF
Dynamique et régulation du niveau de la solution dans le générateur haute température d'un refroidisseur à absorption.
Dynamics and control of solution levels in a high temperature generator for an absorption chiller.
Auteurs : SEO J. A., SHIN Y., CHUNG J. D.
Type d'article : Article, Article de la RIF
Résumé
It is desired to keep the level of a high temperature generator (HTG) solution constant for the purpose of linear controllability and solution economy. Level switches are used to control the solution level. The control of the solution level requires a good flow rate prediction model. It is found that the model can be approximated as a function of HTG solution temperature and coolant inlet temperature. This study identified two aspects of the control strategy for a solution pump inverter that are practiced in the industry: (1) a cut-off frequency of 27 Hz is set up to supply more solution than expected at low HTG temperatures against any possible depletion of solution; and (2) at high HTG temperatures, the sensitivity of the inverter frequency to the cooling water inlet temperature is set to a minimum to reduce solution level fluctuations. This study suggests an improved control algorithm that is proven to have high control performance.
Documents disponibles
Format PDF
Pages : 1123-1129
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Dynamics and control of solution levels in a high temperature generator for an absorption chiller.
- Identifiant de la fiche : 30004207
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 4
- Date d'édition : 06/2012
Liens
Voir d'autres articles du même numéro (45)
Voir la source
-
Capacitance level probes for refrigerants.
- Auteurs : YENCHO J. A.
- Date : 06/03/1994
- Langues : Anglais
- Source : Ammonia: the right stuff.
Voir la fiche
-
THERMAL CONTAMINATION OF CHILLED-WATER SYSTEMS.
- Auteurs : HOPE J. E.
- Date : 07/1990
- Langues : Anglais
- Source : Heat. Pip. Air Cond. - vol. 62 - n. 7
Voir la fiche
-
High efficiency inverter scroll compressors.
- Auteurs : MURAKAMI Y., KITAURA H., MATSUKAWA K., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 23rd International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Méthodes de régulation du variateur de vitesse ...
- Auteurs : MAURO B., KAMZOLOV S.
- Date : 03/2013
- Langues : Russe
- Source : Holodil'nyj Biznes - n. 3
- Formats : PDF
Voir la fiche
-
INDUSTRIAL REFRIGERATION: REGULATION OF REFRIGE...
- Auteurs : BARMWATER P.
- Date : 1987
- Langues : Anglais
- Source : Scand. Refrig./Refrig. Air Cond. Heat Recov. - vol. 90 - n. 1.071
Voir la fiche