A sensible/latent heat separation air conditioning system is expected to realize both thermal comfort and energy conservation simultaneously. In this research, a ceiling radiation panel system and desiccant air conditioning unit was evaluated by simulation in the design phase of a medical facility. Combined use of the ceiling radiation panel system and convection air conditioning made the hospital room comfortable. The simulation showed that the desiccant air conditioning unit used 18 % less cooling energy than did the conventional air conditioning unit. Compared with the conventional air conditioning unit, the desiccant air conditioning unit is advantageous because it can use water at higher temperatures.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy-savings in medical facilities by using sensible/latent heat separation HVAC.
- Identifiant de la fiche : 30008780
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
-
Moisture control and cooling ceiling.
- Auteurs : STEIMLE F.
- Date : 09/09/1997
- Langues : Anglais
- Source : International Symposium on Air Conditioning in High Rise Buildings - 1997
- Formats : PDF
Voir la fiche
-
Développement et étude expérimentale sur le rot...
- Auteurs : OKANO H., HIROSE T.
- Date : 10/2001
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 83
Voir la fiche
-
The energy consumption of a system combining de...
- Auteurs : ZHANG H., NIU J. L.
- Date : 24/10/2000
- Langues : Anglais
- Source : International Symposium on Air Conditioning in High-Rise Buildings - 2000.
- Formats : PDF
Voir la fiche
-
Étude de l'évaluation de la performance d'un hu...
- Auteurs : TANAKA H., NIWA H., BABA H.
- Date : 03/2013
- Langues : Japonais
- Source : Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 192
Voir la fiche
-
A pre-cooling Munters environmental control des...
- Auteurs : ZHANG L. Z., NIU J. L.
- Date : 03/2003
- Langues : Anglais
- Source : Energy, Int. J. - vol. 28 - n. 3
Voir la fiche