Résumé
In this study, an experimental analysis on performance improvement of a diffusion absorption refrigeration system (DARS) was conducted. For the experiment, three DARS cycles were set up and investigated. (i) In the first cycle (DARS-1), representing the most commonly employed model in the industry, the condensate is sub-cooled prior to the evaporator entrance by the coupled evaporator/gas heat exchanger in a similar manner with the refrigeration systems manufactured by Electrolux Sweden [1]. (ii) In the second cycle (DARS-2), the condensate is not sub-cooled prior to the evaporator entrance and the gas heat exchanger is separated from the evaporator as proposed by Zohar et al. [2]. (iii) In the third cycle (DARS-1WE), the novel system being proposed in this study, differing from DARS-1 in certain aspects is used, in which an ejector was installed to the absorber inlet of DARS-1. The weak solution coming from the generator is separated into two parts with equal flows and then one of the parts is connected to the mixing tube of ejector and the other inlet is connected to the absorber. Experimental results show that the DARS-1WE cycle demonstrates a higher performance compared to DARS-1 and DARS-2 cycles. In addition, internal temperature of the cooling area in DARS-1WE decreased to 3.2°C as well. In other words, the duration of attaining the predetermined cooling area temperature decreased even further in DARS-1WE. Consequently, the reduction of energy consumption for relatively low temperatures (6°C) of the cooling area is in the order of 40%. The corresponding level of energy saving falls down to 20% for higher temperatures (10°C).
Détails
- Titre original : The effect of ejector on the performance of diffusion absorption refrigeration systems: An experimental study.
- Identifiant de la fiche : 30005525
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 33-34
- Date d'édition : 02/2012
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2011.09.009
Liens
Voir d'autres articles du même numéro (8)
Voir la source
Indexation
-
Evaluation des performances d'un cycle frigorif...
- Auteurs : BOUMARAF L., HABERSCHILL P.
- Date : 12/2017
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - n.1566
Voir la fiche
-
Performance characteristics of two combined eje...
- Auteurs : ALEXIS G. K., ROGDAKIS E. D.
- Date : 01/2002
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 22 - n. 1
Voir la fiche
-
Single-effect absorption refrigeration cycle bo...
- Auteurs : VEREDA C., VENTAS R., LECUONA A., et al.
- Date : 02/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 38
- Formats : PDF
Voir la fiche
-
Investigation of new cooling cogeneration cycle...
- Auteurs : SHANKAR R., RIVERA W.
- Date : 06/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 114
- Formats : PDF
Voir la fiche
-
Performance investigation and precooler design ...
- Auteurs : MA Y., HU P.
- Date : 06/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 162
- Formats : PDF
Voir la fiche