Résumé

In this study, the effect of insulation on the energy and exergy performances of DAR systems was investigated. A DAR system with the insulated generator-bubble pump (DAR1) was compared with a DAR system having the insulated generator-bubble pump, solution heat exchanger and partial-insulated rectifier (DAR2) experimentally and both components of the DAR1 and the DAR2 systems were insulated by rock wool. In the analyses, the energy losses rejected to ambient from rectifier and condenser, the energy gain (heat gain) by evaporator and also energy performance and exergy performance were calculated. While energy and exergy performances of DAR1 system were determined as 0.35 and 0.095, respectively, the performance values of DAR2 system were calculated as 0.44 and 0.115. As a consequence, the insulation of solution heat exchanger and the insulation of a part of rectifier in the DAR system increased the energy performance by 26% and the exergy performance by 21%.

Documents disponibles

Format PDF

Pages : 161-167

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Effect of insulation on the energy and exergy performances in Diffusion Absorption Refrigeration (DAR) systems.
  • Identifiant de la fiche : 30011846
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 44
  • Date d'édition : 08/2014

Liens


Voir d'autres articles du même numéro (18)
Voir la source