Effet de la modulation de la largeur d'impulsion (MLI) sur la performance d'un évaporateur.
Effect of pulsation width modulation (PWM) on the performance of an evaporator.
Numéro : pap. 2585
Auteurs : WANG X. F., TANG K., HRNJAK P. S.
Résumé
Pulsating flow can increase the heat transfer coefficient when a two-phase flow passes through a single horizontal tube through the following mechanisms: 1) When liquid-vapor two-phase flow and heat transfer occurs inside a tube, flow pulsations can change the flow pattern and increase liquid-wall contact area at a fixed void fraction, thus increasing the heat transfer coefficient; 2) Local pressure at some locations in the tube will drop more with pulsating flow, and the attendant reduction saturation temperature can increase local evaporation and heat transfer. However, the effects of pulsation are more complex for pulsations within a practical evaporator for which the use of a multi-tube construction and the presence of tube bends at the end of each tube certainly affect the resulting flow. In this case, it is anticipated that pulsation width modulation is very important for evaporator performance enhancement. Moreover, local pressure drop in the evaporator increases due to the pulsating flow, and this needs to be taken into account for practical evaporators when considering pulsation as a method of heat transfer performance enhancement. In this work, the effects of pulsation width on heat transfer coefficient and pressure drop in an air-to-refrigerant evaporator have been studied experimentally. An experimental system has been developed with two separate but identical evaporators located in separate but identical wind tunnels. The pulsation width can be controlled with a minimum period of 1s. Average heat transfer coefficient, local heat transfer coefficient and pressure drop have been measured and compared with and without pulsating flow.
Documents disponibles
Format PDF
Pages : 5 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effect of pulsation width modulation (PWM) on the performance of an evaporator.
- Identifiant de la fiche : 30012984
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence
-
An experimentally validated model of single-pha...
- Auteurs : LI W., HRNJAK P.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental investigation of the effects of ai...
- Auteurs : BLECICH P.
- Date : 11/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 59
- Formats : PDF
Voir la fiche
-
REFRIGERANT SIDE HEAT TRANSFER AND PRESSURE DRO...
- Auteurs : TURAGA M., GUY R. W.
- Date : 1985
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 8 - n. 3
- Formats : PDF
Voir la fiche
-
Condensation heat transfer and pressure drop ch...
- Auteurs : MOGHADDAM H. A., SARMADIAN A., ASNAASHARI A., JOUSHANI H. A. N., ISLAM M. A, SAHA S. C., GHASEMI G., SHAFAEE M.
- Date : 10/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Formats : PDF
Voir la fiche
-
Condensing two-phase pressure drop and heat tra...
- Auteurs : LÓPEZ BELCHÍ A., ILLÁN GÓMEZ F., GARCÍA-CASCALES J. R., et al.
- Date : 08/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 68
- Formats : PDF
Voir la fiche