Résumé
VRF system has generally large size outdoor unit which can cover big capacity. Large size outdoor heat exchanger requires many refrigerant paths, because of pressure drop during evaporation and condensation. The increase of refrigerant path number may cause mal-distribution of refrigerant. Especially, heat exchangers which have vertically long geometry and uneven air velocity profile have very serious refrigerant distribution problem. The appropriate differential refrigerant flowrate control can lead to the increase of heat exchanger performance. The distribution problems are more important for high efficient evaporator. In this paper, how to control refrigerant flowrate using small diameter tubes after distributor will be introduced. And we will review the effect of the appropriate refrigerant flowrate control of outdoor heat exchanger. Our result showed that the decrease of the standard deviation of evaporator outlet temperatures of 1°C can lead to the heating COP increase of nearly 10%.
Documents disponibles
Format PDF
Pages : 6 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The effect of refrigerant flowrate control of outdoor heat exchanger.
- Identifiant de la fiche : 30000981
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 12/07/2010
Liens
Voir d'autres communications du même compte rendu (121)
Voir le compte rendu de la conférence
-
New generation of air-cooled heat exchanger 1 k...
- Auteurs : SALEH K., ABDELAZIZ O., AUTE V., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
EVAPORATEURS FRIGORIFIQUES MULTITUBULAIRES : RE...
- Auteurs : BASTARD J., MAMAN A.
- Date : 1987
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - vol. 40 - n. 644
Voir la fiche
-
Heat exchanger area ratio models for refrigeran...
- Auteurs : PRAPAINOP R., SUEN K. O., COLBOURNE D.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche
-
Mitigation of air flow maldistribution in evapo...
- Auteurs : BACH C. K., GROLL E. A., BRAUN J. E., et al.
- Date : 12/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 73 - n. 1
Voir la fiche
-
Echangeurs thermiques. Méthodes de mesurage des...
- Auteurs : AFNOR
- Date : 11/1997
- Langues : Français
Voir la fiche