Document IIF

Effet de la technique d'injection de vapeur sur la performance d'un chauffe-eau à pompe à chaleur en cascade.

Effect of vapor-injection technique on the performance of a cascade heat pump water heater.

Auteurs : ROH C. W., KIM M. S.

Type d'article : Article, Article de la RIF

Résumé

In this study, we applied a vapor-injection (VI) technique in a cascade heat pump system. The VI was applied to both upper and lower stage cycles. Test results showed that heating and cooling capacities increased by using the VI technique (12% and 6%, respectively); however, the system COP decreased (6.6% at the injection ratio of 16.7%). The cascade system which has a small compression ratio and a cascade condenser, cannot fully utilize the VI's advantages to improve the system COP. However, the VI is effective for the system reliability and capacity improvement. We also found that the VI in the upper and lower stage cycles had different effect on overall cycle operating characteristic.

Documents disponibles

Format PDF

Pages : 168-177

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Effect of vapor-injection technique on the performance of a cascade heat pump water heater.
  • Identifiant de la fiche : 30010357
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 38
  • Date d'édition : 02/2014

Liens


Voir d'autres articles du même numéro (34)
Voir la source