Document IIF
Effet des paramètres de conception des ailettes sur la performance d’un refroidisseur à adsorption à deux lits.
Effect of fin design parameters on the performance of a two-bed adsorption chiller.
Auteurs : ABD-ELHADY M. S., HAMED A. M.
Type d'article : Article de la RIF
Résumé
Adsorption refrigeration systems are commercially matured due to the need of decreasing electrical power consumption and usage of non-environmental refrigerants, which are the main problems of the conventional refrigeration systems. This paper presents an investigation on the performance of small-scale two-bed adsorption chiller combined with heat and mass recovery cycles with the aid of a lumped analytical simulation technique. This model is applied to analyze the effect of fin design parameters on the heat transfer inside the bed and system performance. The working pair used in the simulations is RD silica gel–water. Defining a base-case for the fin design parameters, fin thickness, fin radius, and fin spacing are changed and the performances of four fin configurations are demonstrated. Decreasing the fin spacing enhances the heat transfer significantly. For optimum operation condition, specific cooling capacity is improved by an average value up to 147.6% by decreasing fin spacing from 4 mm to 2 mm, while increasing the fin radius decreases temperatures of the adsorbent. Specific cooling capacity is improved by an average value up to 44% by decreasing fin radius from 16 mm to 8 mm. The fin thickness has a minor effect on heat transfer in the bed.
Documents disponibles
Format PDF
Pages : 164-173
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effect of fin design parameters on the performance of a two-bed adsorption chiller.
- Identifiant de la fiche : 30027424
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 113
- Date d'édition : 05/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.01.006
Liens
Voir d'autres articles du même numéro (28)
Voir la source
Indexation
-
Multi-bed regenerative adsorption chiller: impr...
- Auteurs : CHUA H. T., NG K. C., MALEK A., et al.
- Date : 03/2001
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 24 - n. 2
- Formats : PDF
Voir la fiche
-
Nouvelle analyse paramétrique d'un refroidisseu...
- Auteurs : ALAM K. C. A., SAHA B. B., AKISAWA A., et al.
- Date : 2000
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 17 - n. 3
Voir la fiche
-
Two bed silica gel-water adsorption chillers: a...
- Auteurs : WANG X. L., CHUA H. T.
- Date : 12/2007
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 8
- Formats : PDF
Voir la fiche
-
Theoretical and experimental study on character...
- Auteurs : DI J., WU J. Y., XIA Z. Z., et al.
- Date : 05/2007
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 3
- Formats : PDF
Voir la fiche
-
Analyse numérique d'un cycle frigorifique à ads...
- Auteurs : AKAHIRA A., AMANUL ALAM K. C., HAMAMOTO Y., et al.
- Date : 2002
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 19 - n. 4
Voir la fiche