Document IIF
Effet du type et de l'humidité du sol sur la performance des pompes à chaleur à capteurs enterrés.
Effect of soil type and moisture content on ground heat pump performance.
Auteurs : LEONG W. H., TARNAWSKI V. R., AITTOMÄKI A.
Type d'article : Article, Article de la RIF
Résumé
Three different soils (sand, silty loam and silty clay) with five different degrees of saturation (0, 12.5, 25, 50 and 100%) were used in computer simulations. The performance of a ground heat pump system was found to depend strongly on the moisture content and the soil type (mineralogical composition). Alteration of soil moisture content from complete dryness to 12.5% of stauration strongly influences the ground heat pump performance, and any decrease of soil moisture in this range has a devastating effect on the COP. Therefore, it is beneficial to keep the soil moisture value as high as possible above dry soil conditions. Soil moisture content above the quarter saturation state leads to a much better heat pump performance. It was found, however, that the effect of moisture content variation above 50% of saturation on ground heat pump performance is relatively insignificant.
Documents disponibles
Format PDF
Pages : 595-606
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effect of soil type and moisture content on ground heat pump performance.
- Identifiant de la fiche : 1999-1181
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 21 - n. 8
- Date d'édition : 12/1998
Liens
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
- Thèmes : Techniques des pompes à chaleur
- Mots-clés : Propriété thermique; Sol; Pompe à chaleur; Performance; Échangeur de chaleur
-
Heat transfer in ground heat exchangers with gr...
- Auteurs : DIAO N., LI Q., FANG Z.
- Date : 12/2004
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 43 - n. 12
Voir la fiche
-
Heat dissipation effect on a borehole heat exch...
- Auteurs : DARKWA J., SU W., CHOW D. H. C.
- Date : 10/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 60 - n. 1-2
Voir la fiche
-
Experimental investigation of the cooling perfo...
- Auteurs : KARABACAK R., ACAR S. G., KUMSAR H., et al.
- Date : 03/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 2
- Formats : PDF
Voir la fiche
-
OPERATING EXPERIENCE WITH GROUND-SOURCE HEAT PU...
- Auteurs : NISHIOKA J.
- Date : 12/03/1990
- Langues : Anglais
Voir la fiche
-
SPIRAL GROUND HEAT EXCHANGERS FOR HEAT PUMP APP...
- Auteurs : SVEC O. J.
- Date : 12/03/1990
- Langues : Anglais
Voir la fiche