Effet du volume du tube à pulsation sur les dynamiques d'un compresseur linéaire et la performance d'un réfrigérateur à tube à pulsation de type Stirling.
Effect of a pulse tube volume on the dynamics of a linear compressor and the cooling performance in a Stirling-type pulse tube refrigerator.
Résumé
In a Stirling-type pulse tube refrigerator (PTR), the pulse tube volume affects the dynamic behaviour of a linear compressor as well as the cooling performance of PTR. In this study, PTRs which have different pulse tube volume are tested and simulated. The simulation code is verified with the experimental measurement of piston displacement, pressure wave, input power and cooling capacity. And then, the power transfer from the electric power input to the cooling capacity is explained with the simulation results. The smaller pulse tube increases the resonant frequency of a linear compressor and suppresses the piston motion because it imposes larger gas spring effect and also larger gas damping effect to the piston. The smaller one allows larger power transfer from electric power to expansion PV work despite the smaller piston displacement, but shows less cooling capacity due to larger thermal losses. [Reprinted with permission from Elsevier. Copyright, 2009].
Détails
- Titre original : Effect of a pulse tube volume on the dynamics of a linear compressor and the cooling performance in a Stirling-type pulse tube refrigerator.
- Identifiant de la fiche : 2010-0670
- Langues : Anglais
- Source : Cryogenics - vol. 50 - n. 1
- Date d'édition : 01/2010
- DOI : http://dx.doi.org/10.1016/j.cryogenics.2009.08.008
Liens
Voir d'autres articles du même numéro (1)
Voir la source
Indexation
-
Refrigeration performance study on pulse tube r...
- Auteurs : CHEN G. B., TANG K., JIN T., et al.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche
-
Performance of pulse-tube refrigerators in cryo...
- Auteurs : FUJISAWA Y., SHIRAISHI M., IKEGUCHI T., et al.
- Date : 22/07/2002
- Langues : Anglais
- Source : Proceedings of the nineteenth International Cryogenic Engineering Conference. ICEC 19.
Voir la fiche
-
A single-stage pulse tube cooler working at 11 K.
- Auteurs : HE Y. L., QIU L. M., GAN Z. H., et al.
- Date : 17/07/2006
- Langues : Anglais
- Source : Multiconference CryoPrague 2006 (9th Cryogenics 2006, ICEC 21, ICMC'06)
- Formats : PDF
Voir la fiche
-
Increase in performance of a 4 K pulse tube cry...
- Auteurs : REVEX A., TROLLIER T., TANCHON J., et al.
- Date : 17/07/2006
- Langues : Anglais
- Source : Multiconference CryoPrague 2006 (9th Cryogenics 2006, ICEC 21, ICMC'06)
- Formats : PDF
Voir la fiche
-
Développement d'un cryoréfrigérateur à tube à p...
- Auteurs : XU M., NAKANO K., TAKAYAMA H., et al.
- Date : 07/2013
- Langues : Japonais
- Source : Journal of Cryogenics and Superconductivity Society of Japan - vol. 48 - n. 7
Voir la fiche