Résumé
The present study numerically investigated the geometric effect on the thermal performance of a high temperature generator (HTG) of a double effect LiBr-water absorption system with the cooling capacity of 210 refrigeration tons. The HTG tubes were located behind a pre-mixed surface burner. The HTG was consisted with a set of circular tubes and flattened tubes in series. LiBr aqueous weak solution was flowed into the generator tube, and then turned into strong solution at the exit of the HTG tubes. FLUENT, as a commercial code, was used to estimate the thermal performance of the HTG. Standard kappa-epsilon model was applied for combustion gas-side turbulent flow around the HTG tubes. Key parameters were heat transfer area and spacing ratio of flattened tubes in HTG. Temperature profiles around the HTG tubes were numerically calculated to estimate the thermal performance of the HTG and to find out the optimal condition. The minimum exhaust temperature of the HTG was 164°C at the spacing ratio of flattened tube of 0.73.
Documents disponibles
Format PDF
Pages : ICR07-B1-673
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Geometric effect on the performance of a high temperature generator of the absorption system.
- Identifiant de la fiche : 2008-0180
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Systèmes à absorption et adsorption
- Mots-clés : Géometrie; Générateur; Tube; Système à absorption; Simulation; Performance; Modélisation; Eau-bromure de lithium
-
Effect of the geometry of flattened tube on the...
- Auteurs : LEE I., CHO K.
- Date : 06/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 4
- Formats : PDF
Voir la fiche
-
Efficiency and outlook for lithium bromide abso...
- Auteurs : TIMOFEEVSKIJ L. S., BARANENKO A. V., DZINO A. A., DOLOTOV A. G., GERTSEN V. N., SHEN J.
- Date : 21/04/1998
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR '98.
Voir la fiche
-
Theoretical analysis of low-temperature hot sou...
- Auteurs : MA W. B., DENG S. M.
- Date : 02/1996
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 19 - n. 2
- Formats : PDF
Voir la fiche
-
Analytical and experimental study on the absorp...
- Auteurs : KIM J., CHO K.
- Date : 24/09/2002
- Langues : Anglais
- Source : Proceedings of the International Sorption Heat Pump Conference.
Voir la fiche
-
Optimal design of compact horizontal tube LiBr/...
- Auteurs : JEONG S., GARIMELLA S.
- Date : 01/2005
- Langues : Anglais
- Source : HVAC&R Research - vol. 11 - n. 1
Voir la fiche