Effets de la configuration des buses sur un évaporateur à aspersion multitubulaire avec récupération de liquide.
Effects of nozzle configuration on a shell-and-tube spray evaporator with liquid catcher.
Auteurs : CHANG T. B.
Type d'article : Article
Résumé
Using R141b as a coolant, this study investigates the efficiency of impact spray cooling heat transfer in a heat exchanger system comprising a horizontal low-finned tube bundle with a triangular-pitch and a fin count of 1000 fins/m. Each copper tube has a base diameter of 19.1 mm and is heated by an electrical resistor. The average heat transfer coefficients are calculated by measuring the mean tube surface temperature and the vapour temperature. Six different nozzle configurations are tested to investigate the effect of the nozzle configuration on the spray evaporation heat transfer performance. It is found that the shell-side heat transfer performance depends significantly on the nozzle orifice diameter, the heat flux rate, and the spray mass flow rate, but is influenced only slightly by the height of the nozzle above the upper row of tubes in the bundle. The dry-out phenomenon is observed as the surface heat flux increases. Under these conditions, the spray cooling heat transfer coefficients are less than those obtained in pool boiling. To overcome the dry-out problem, this study fits liquid catchers beneath each tube. The experimental results show that the heat transfer performance for spray cooling with liquid catchers is superior to that of pool boiling under both low and high heat fluxes. Moreover, the influence of the nozzle configuration on the heat transfer performance is significantly reduced when liquid catchers are attached. [Reprinted with permission from Elsevier. Copyright, 2005].
Détails
- Titre original : Effects of nozzle configuration on a shell-and-tube spray evaporator with liquid catcher.
- Identifiant de la fiche : 2006-2324
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 26 - n. 8-9
- Date d'édition : 06/2006
Liens
Voir d'autres articles du même numéro (8)
Voir la source
Indexation
-
Boiling heat transfer enhancement by thermal sp...
- Auteurs : ASANO H., TOMITA R., INOUE M., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche
-
Air cooling by evaporating droplets in the upwa...
- Auteurs : TISSOT J., BOULET P., TRINQUET F., et al.
- Date : 11/2011
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 50 - n. 11
Voir la fiche
-
Limited charge shell-and-tube ammonia spray eva...
- Auteurs : AYUB Z.
- Date : 16/06/2010
- Langues : Anglais
- Source : RCR 2010. 2nd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Stockholm, Sweden, June 16-17, 2010.
- Formats : PDF
Voir la fiche
-
Electrohydrodynamic boiling enhancement in shel...
- Auteurs : DAMIANIDIS C., KARAYIANNIS T. G., DADAH R. K. al-, JAMES R. W., COLLINS M. W., ALLEN P. H. G.
- Date : 1992
- Langues : Anglais
- Source : ASHRAE Transactions 1992. Part 2.
Voir la fiche
-
Heat transfer enhancement in evaporation by the...
- Auteurs : ASANO H., TOMITA R., SHIGEHARA R., et al.
- Date : 17/02/2010
- Langues : Anglais
- Source : Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
Voir la fiche