Document IIF
Effets de la génération de "flash gaz" à l'entrée du détendeur sur les caractéristiques dynamiques d'un système frigorifique.
Effects of flash gas generation at the expansion device inlet on the dynamic characteristics of a refrigeration system.
Résumé
The flash gas generation at the expansion device inlet in multi-air-conditioners causes rapid reduction of refrigerant mass flow rate and irregular distribution of refrigerant into multi-indoor units. The objective of this study is to evaluate the influence of the flash gas generation on the dynamic characteristics of a refrigeration system. The dynamic characteristics of a refrigeration system with an electronic expansion valve (EEV) were measured with time at various levels of flash gas generation, which were expressed as flash gas ratio. In addition, the averaged operating parameters and system COP were investigated with the variation of flash gas ratio. As the EEV inlet condition changed from the subcooled to the two-phase state, the refrigerant flow rate decreased rapidly due to the flash gas generation at the EEV inlet. At two-phase inlet conditions, the system operating parameters, such as mass flow rate, suction and discharge pressures, fluctuated periodically with time. As the flash gas ratio increased, the average COP decreased and the discharge temperature increased, degrading the system performance and reliability more severely.
Documents disponibles
Format PDF
Pages : 396-403
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effects of flash gas generation at the expansion device inlet on the dynamic characteristics of a refrigeration system.
- Identifiant de la fiche : 2008-0613
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 3
- Date d'édition : 05/2008
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Thèmes :
Systèmes de détente;
Conditionnement d'air pour le confort;
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité - Mots-clés : Écoulement diphasique; Système frigorifique; Grande hauteur; Gaz; Toiture; Détendeur électronique; Immeuble; Conditionneur d'air; Performance; Paramètre; Détente
-
COMMANDE ELECTRONIQUE D'UN DETENDEUR.
- Auteurs : FUJIMAKI S., TANAKA T.
- Date : 1984
- Langues : Japonais
- Source : Refrigeration - vol. 59 - n. 682
Voir la fiche
-
Simulation analysis on variable speed air condi...
- Auteurs : ZHANG L., LIU C.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
A method for modelling adjustable throat-area e...
- Auteurs : LI H., BRAUN J. E.
- Date : 07/2008
- Langues : Anglais
- Source : HVAC&R Research - vol. 14 - n. 4
Voir la fiche
-
Multiple packaged rooftop unit coordination for...
- Auteurs : DEVENEZIA J., ROSSI T., MULLER M. R.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 7th International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental comparison of electronic and therm...
- Auteurs : LAZZARIN R., NORO M.
- Date : 01/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 1
- Formats : PDF
Voir la fiche