Essais de divers concepts de distribution d'air pour une cabine d'avion à allée unique.

Test of different air distribution concepts for a single-aisle aircraft cabin.

Numéro : 832

Auteurs : NIELSEN P. V., DAMSGAARD C., LIU L., et al.

Résumé

Traditionally, air is supplied to the aircraft cabin either by individual nozzles or by supply slots. The air is expected to be fully mixed in the cabin, and the system is considered to be a mixing ventilation system. This paper will describe different air distribution systems known from other applications namely: the traditional mixing ventilation, displacement ventilation, downward ventilation and finally a personalized ventilation system as well, which is used in addition to the other systems. The experiments are made in a full-scale left side section of a single-aisle (Boeing 737) cabin with four seats. The four persons are simulated by thermal manikins. Velocity, temperature and cross-infection risk are measured by hot spheres, thermocouples and tracer gas.

Documents disponibles

Format PDF

Pages : 9 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Test of different air distribution concepts for a single-aisle aircraft cabin.
  • Identifiant de la fiche : 30009955
  • Langues : Anglais
  • Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
  • Date d'édition : 16/06/2013

Liens


Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence