Document IIF
Étalonnage basé sur la mesure de masse d’un capteur capacitif pour mesurer la fraction de vide pour le R134a dans des tubes lisses.
Mass measurement based calibration of a capacitive sensor to measure void fraction for R134a in smooth tubes.
Résumé
This paper presents a new capacitive sensor built and used to measure void fraction of both horizontal and vertical upward flow in the low mass flux range in circular tubes with an inner diameter of 7 mm. Three sensors with different axial lengths (D, 2D/3, and D/2) are built and evaluated to examine the pos- sibility of utilizing shorter sensors in applications with space limitations. Results show all three sensors have the capability to measure void fraction. Due to the nonlinear relation between capacitive signals and void fraction, a calibration procedure based on mass measurement (quick-closing valve technique, QCV) is proposed. After the calibration procedure, most void fraction data measured by the sensor falls into the ±15% deviations of the experimental results by QCV for horizontal flow and ±10% for vertical upward flow. Sensors with the same design can be utilized directly to measure void fraction for the similar test conditions in the future studies.
Documents disponibles
Format PDF
Pages : 168-177
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Mass measurement based calibration of a capacitive sensor to measure void fraction for R134a in smooth tubes.
- Identifiant de la fiche : 30027297
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 110
- Date d'édition : 02/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.10.019
Liens
Voir d'autres articles du même numéro (29)
Voir la source
Indexation
-
Thèmes :
HFC;
Ecoulement diphasique - Mots-clés : Écoulement diphasique; R134a; Capteur; Étalonnage; Tube; Experimentation
-
Signal analysis and mass measurement based cali...
- Auteurs : QIAN H., HRNJAK P.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Characterization of R134a two-phase flow regime...
- Auteurs : QIAN H., HRNJAK P.
- Date : 05/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 125
- Formats : PDF
Voir la fiche
-
Effects of boiling hysteresis on metastable two...
- Auteurs : GAO L., EGUCHI H., TATARA Y., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Flow visualization of R134a, R1234ze(E), and R1...
- Auteurs : LI H., HRNJAK P.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Void fraction and flow regimes of R134a in hori...
- Auteurs : QIAN H., HRNJAK P.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche