Document IIF
Étude comparative des performances des caissons de déshumidification à déshydratant à un et deux étages dans des conditions climatiques chaudes et humides.
Comparative investigation on performance of single-stage and double-stage desiccant dehumidification boxes under hot-humid climatic conditions.
Résumé
Desiccant fixed bed is a prospective alternative for conventional vapor compression refrigeration system. In this paper, a novel structure of fixed bed, desiccant dehumidification box, was constructed and experimented at a sub-tropical city, Guangzhou. Dehumidification performance of the new structure was evaluated by several indicators. Mathematical models were established concerning moisture adsorption rate and moisture ratio. The adsorption heat generated was analyzed by testing sensible heat gain of the process air and heat storage of the desiccant. The result shows that the double-stage desiccant dehumidification box could perform better generally. The maximum dehumidification capacity could reach 3.9 g•kg−1 and 1.6 g•kg−1 on average in condition 4. Maximum dehumidification efficiency (27.8%) was obtained in the same condition when applying the double-stage box. The desiccant saturated at about 6 h in experiments, of which variation in the double-stage box was more stable and lasting, though moisture adsorption rate presents only a little difference in comparison boxes. Exponential models fit the practical curves within 10% relative error. Maximum average temperature rise of the desiccant and process air was 4.3°C and 3.8°C respectively in the double-stage box, which was 0.4°C and 0.9°C higher than the single-stage box. Around 97% of the adsorption heat was directed to heat storage of the desiccant and only left 3% directed to sensible heat gain of the process air.
Documents disponibles
Format PDF
Pages : 1-14
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparative investigation on performance of single-stage and double-stage desiccant dehumidification boxes under hot-humid climatic conditions.
- Identifiant de la fiche : 30030837
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 146
- Date d'édition : 02/2023
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.10.015
Liens
Voir d'autres articles du même numéro (41)
Voir la source
-
Limitations and feedback effects in liquid desi...
- Auteurs : BUCHIN O., ZIEGLER F.
- Date : 02/03/2014
- Langues : Anglais
- Source : International sorption heat pump conference (ISHPC2014), College Park, United States, March 31-April 2, 2014.
- Formats : PDF
Voir la fiche
-
Two stage regeneration of liquid desiccant usin...
- Auteurs : RANE M. V., MEHTA M. J.
- Date : 02/03/2014
- Langues : Anglais
- Source : International sorption heat pump conference (ISHPC2014), College Park, United States, March 31-April 2, 2014.
- Formats : PDF
Voir la fiche
-
An experimental study on air leakage and perfor...
- Auteurs : PI C. H., CHANG Y. S., KANG B. H.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Potential study of desiccant wheel-based water ...
- Auteurs : GLÜCK C., ROLDAN BLASCO E., LENZ B., et al.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Novel desiccant cooling system using indirect e...
- Auteurs : BELDING W. A., DELMAS M. P. F.
- Date : 1997
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche