Étude d'un cryorefroidisseur Joule-Thomson à mélange de frigorigènes néon-azote opérant en dessous de 70 K avec prérefroissement à 100 K.
Investigation of neon-nitrogen mixed refrigerant Joule-Thomson cryocooler operating below 70 K with precooling at 100 K.
Résumé
There has been two-stage mixed refrigerant (MR) Joule-Thomson (JT) refrigeration cycle suggested for cooling high temperature superconductor (HTS) electric power cable below 70 K. As the continuation effort of realizing the actual system, we fabricated and tested a small scale neon and nitrogen MR JT cryocooler to investigate the refrigeration characteristics and performance. The compression system of the refrigeration circuit was accomplished by modifying commercially available air-conditioning rotary compressors. Compressors stably operated at the maximum compression ratio of 31 when the suction pressure was 77 kPa. The achieved lowest temperature was 63.6 K when the heating load was 35.9 W. The measured Carnot efficiency of the present system was 6.5% which was lower than that of the designed goal of 17.4%. The low efficiency of compressor (34.5%), and the pressure drop at the compressor suction were the main reasons for this efficiency degradation. The feasibility and usefulness of neon and nitrogen MR JT refrigeration cycle was validated that the achieved minimum temperature was 63.6 K even though the pressure after the expansion was maintained by 130 kPa. The comparison between the measurement and calculation showed that each stream temperature of refrigeration cycle were predictable within 3% error by Peng–Robinson equation of state (EOS).
Détails
- Titre original : Investigation of neon-nitrogen mixed refrigerant Joule-Thomson cryocooler operating below 70 K with precooling at 100 K.
- Identifiant de la fiche : 30012125
- Langues : Anglais
- Source : Cryogenics - vol. 61
- Date d'édition : 05/2014
- DOI : http://dx.doi.org/10.1016/j.cryogenics.2014.02.006
Liens
Voir d'autres articles du même numéro (6)
Voir la source
Indexation
-
Design of non-flammable mixed refrigerant Joule...
- Auteurs : LEE C., JIN L., PARK C., et al.
- Date : 11/2016
- Langues : Anglais
- Source : Cryogenics - vol. 81
Voir la fiche
-
Design of high efficiency mixed refrigerant Jou...
- Auteurs : LEE J., HWANG G. W., JEONG S., et al.
- Date : 07/2011
- Langues : Anglais
- Source : Cryogenics - vol. 51 - n. 7
Voir la fiche
-
Experimental research on a new type of mixed-re...
- Auteurs : WANG Z. X., GONG M. Q., LIU J. Y., et al.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche
-
Design of a high-current cryogenic test stand f...
- Auteurs : ARNSBERG J., STAMM M., GROHMANN S.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Experimental investigation of a mixed-refrigera...
- Auteurs : LUO E. C., GONG M. Q., ZHOU Y.
- Date : 21/04/1998
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR '98.
Voir la fiche