Étude de cas portant sur la détection et le diagnostic des pannes dans un conditionneur d'air ménager à l'aide d'un simulateur dynamique du cycle frigorifique.

Case study of fault detection and diagnosis of a household air conditioner with a dynamic refrigeration cycle simulator.

Auteurs : SEO J. A., LIM T. H., SHIN Y., et al.

Type d'article : Article

Résumé

A high fidelity refrigeration cycle simulator was developed using the moving boundary method and the simulator's performance was confirmed with test data of a household air conditioner. The simulator showed a good agreement with the test data. The simulator was applied as a virtual test bed to generate normal and faulty operation data which were needed to develop FDD algorithm. To evaluate the feasibility of the simulator for FDD development, a typical time-varying cooling load was generated and normal and faulty cases were simulated. Steady state filter was constructed from moving average and standard deviation. Evaporator fouling was diagnosed by comparing estimated UA at a given fan speed with normal UA at the same fan speed. Superheat cannot be controlled when an EEV gets stuck. Time-integrated superheat error was found to be a good indicator to detect the fault.

Détails

  • Titre original : Case study of fault detection and diagnosis of a household air conditioner with a dynamic refrigeration cycle simulator.
  • Identifiant de la fiche : 30016923
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 94
  • Date d'édition : 05/02/2016
  • DOI : http://dx.doi.org/10.1016/j.applthermaleng.2015.10.037

Liens


Voir d'autres articles du même numéro (46)
Voir la source