Investigation of air-cooled condensers for ammonia-water absorption chillers.
Étude de condenseurs à air pour refroidisseurs à absorption à ammoniac-eau.
Numéro : pap. 2270
Auteurs : CHAKRABORTY S., AIELLO V. C., GARIMELLA S.
Résumé
This paper presents the results from experimental and analytical investigation of air-cooled condensers for use in small-scale, direct-fired ammonia-water absorption chillers. Two novel multi-pass tube-array condensers, compatible with ammonia-water refrigerant mixture, are designed, fabricated and evaluated. The condensers are built for an absorption system that delivers 2.71 kW cooling capacity in severe ambient temperatures as high as 52°C with a design condenser heat rejection rate of 2.51 kW into ambient air. A single-pressure ammonia-water test facility is constructed and used in conjunction with a temperature- and humidity-controlled air-handling unit to evaluate the condensers at design and off-design operating conditions. Condenser performance is recorded over a range of air temperatures, refrigerant temperatures, air volumetric flow rates, and refrigerant mass flow rates. The maximum ambient temperatures and minimum air flow rates required to reject design heat duty are identified for both the condensers. A heat transfer model is developed for the first condenser, which is determined to be air-side limited. The model
predictions are compared with the measured heat transfer rates at various ambient conditions and the deviations explained. Results from this investigation guide the development of air-coupled zeotropic mixture condensers for compact absorption heat pumps.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Investigation of air-cooled condensers for ammonia-water absorption chillers.
- Identifiant de la fiche : 30018865
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 11/07/2016
Liens
Voir d'autres communications du même compte rendu (274)
Voir le compte rendu de la conférence
-
The ammonia-water absorption refrigerating plan...
- Auteurs : PORNEALA S., NEAGU M., PORNEALA C.
- Date : 2000
- Langues : Anglais
- Source : Ann. Univ. Dunarea Jos Galati, IV - vol. 15
Voir la fiche
-
Generalized transient simulation of two-phase h...
- Auteurs : GOYAL A., GARIMELLA S.
- Date : 09/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 105
- Formats : PDF
Voir la fiche
-
Design of cross-flow condensers for ammonia-wat...
- Auteurs : GARIMELLA S., COLEMAN J. W.
- Date : 1998
- Langues : Anglais
- Source : ASHRAE Transactions. 1998 Winter Meeting, San Francisco, CA.
Voir la fiche
-
Un absorbeur à film tombant eau-ammoniac au ban...
- Auteurs : TRICHE D., BONNOT S., PERIER-MUZET M., et al.
- Date : 01/2017
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - n.1161
Voir la fiche
-
Investigation of a serpentine micro-pin fin hea...
- Auteurs : HOYSALL D. C., GARIMELLA S.
- Date : 09/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 93
- Formats : PDF
Voir la fiche