Document IIF
Étude de la performance énergétique annuelle d'un système de pompe à chaleur aérothermique à débit d’eau variable.
Investigation of annual energy performance of a VWV air source heat pump system.
Auteurs : WANG R. Z., JIN Z. Q., ZHAI X. Q., et al.
Type d'article : Article, Article de la RIF
Résumé
This work studies the annual energy performance of a Variable Water Volume (VWV) air source heat pump (ASHP) system by means of experiment and simulation. An advanced R410A ASHP system, integrated with independent normal fan coil unit, small temperature difference fan coil unit and floor radiation heating coil unit indoor terminals, is constructed. Multi-groups of field tests show that system COP varies from 2.0~4.0 for the different operating load under corresponding conditions. Moreover, in order to predict the long term energy performance of the ASHP system, several quasi-steady models are constructed and validated with experimental data. Then the annual energy performances of investigated system are simulated under different climate zones in China. Both experimental and simulation results show that VWV ASHP system can achieve high competitive seasonal energy efficiency for the buildings, which shows the SPF could be more than 3.0. At last, several recommendations based on the simulation results are proposed to the existed heat pump system.
Documents disponibles
Format PDF
Pages : 383-394
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Investigation of annual energy performance of a VWV air source heat pump system.
- Identifiant de la fiche : 30022904
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Date d'édition : 01/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.10.015
Liens
Voir d'autres articles du même numéro (36)
Voir la source
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
HFC - Mots-clés : Débit variable; R410A; Système aérothermique; Simulation; Pompe à chaleur; Experimentation; Efficacité énergétique
-
Experimental study of an improved air-source he...
- Auteurs : XIAO B., HUANG T., HE L., et al.
- Date : 04/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 100
- Formats : PDF
Voir la fiche
-
Experimental study on heat pump space heating s...
- Auteurs : YANG C., ZENG D.
- Date : 20/07/2017
- Langues : Anglais
- Source : 8th international conference on compressors and refrigeration, 2017.
- Formats : PDF
Voir la fiche
-
Model-free control of vapor-injection air-sourc...
- Auteurs : WANG W., LI Y., CAO F.
- Date : 20/07/2017
- Langues : Anglais
- Source : 8th international conference on compressors and refrigeration, 2017.
- Formats : PDF
Voir la fiche
-
Cálculo del rendimiento estacional de bombas de...
- Auteurs : SIERES J., ORTEGA I., CERDEIRA F., ALVAREZ E., SANTOS J. M.
- Date : 04/2022
- Langues : Espagnol
- Source : XI Congreso Ibérico y IX Congreso Iberoamericano de Ciencias y Técnicas del Frío, CYTEF 2022.
- Formats : PDF
Voir la fiche
-
Analysis of the refrigerant‐side temperature pr...
- Auteurs : SIERES J., ORTEGA I., CERDEIRA F., SANTOS J. M., ALVAREZ E.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche