ETUDE DE LA REGION D'ECOULEMENT SOUS-REFROIDI D'UN ECHANGEUR DE CHALEUR CONSTITUE PAR LE TUBE CAPILLAIRE ET LA CONDUITE D'ASPIRATION.

A STUDY OF THE SUBCOOLED FLOW REGION OF A CAPILLARY TUBE-SUCTION LINE HEAT EXCHANGER.

Auteurs : PATE M. B., TREE D. R.

Résumé

UN ECHANGEUR DE CHALEUR CONSTITUE PAR LE TUBE CAPILLAIRE ET LA CONDUITE D'ASPIRATION A ETE EQUIPE D'INSTRUMENTS POUR MESURER LES PRESSIONS, LES TEMPERATURES DE PAROI ET LA TEMPERATURE DU FLUIDE DE LA CONDUITE D'ASPIRATION AINSI QUE LES DEBITS-MASSES DE FLUIDE. UN MODELE DE REGIME PERMANENT A ETE MIS AU POINT POUR LA REGION D'ECOULEMENT SOUS-REFROIDI. CE MODELE A ETE COMPLIQUE PAR LE FAIT QUE LA CHALEUR SE DEGAGEAIT DE LA PAROI DE L'ECHANGEUR DE CHALEUR VERS L'ENVIRONNEMENT. ON A MONTRE QUE LE MODELE QUI SE COMPARAIT DE FACON SATISFAISANTE AVEC LES RESULTATS EXPERIMENTAUX ETAIT TRES SENSIBLE AUX ERREURS SUR LES ETATS INITIAUX D'ENTREE PAR SUITE DE FAIBLES ABAISSEMENTS DE LA TEMPERATURE SUPERFICIELLE DU COTE DE L'ASPIRATION ET DE LA NATURE DE LA PROPAGATION DE LA SOLUTION. IL ETAIT AUSSI TRES SENSIBLE AUX PERTES DE CHALEUR DE LAPAROI ET AU COEFFICIENT DE TRANSFERT DE CHALEUR DU COTE DE L'ASPIRATION. UNE COMPARAISON AVEC ETAIT LA PLUS PRECISE.

Détails

  • Titre original : A STUDY OF THE SUBCOOLED FLOW REGION OF A CAPILLARY TUBE-SUCTION LINE HEAT EXCHANGER.
  • Identifiant de la fiche : 1988-1389
  • Langues : Anglais
  • Date d'édition : 01/09/1986
  • Source : Source : Proc. int. Symp. Heat Mass Transf. Refrig. Cryog., Dubr.
    165-186; 18 fig.; 12 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.