Etude des caractéristiques transitoires d'un cryogénérateur Joule-Thomson autorégulé.

A study of the transient characteristics of a self-regulating Joule-Thomson cryocooler.

Auteurs : CHIEN S. B., CHEN L. T., CHOU F. C.

Type d'article : Article

Résumé

An experimental and numerical study of transient characteristics for the self-regulating Joule-Thomson cryocooler is developed in the paper. It is proved by experiment that the most important transient behaviours can be accurately predicted by this numerical simulation. The study also proposes a revised design to improve temperature stability. The revised dual-orifice Joule-Thomson cooler can effectively reduce the phenomena of unstable temperature and mass flow rate, but sacrifices the expected gas consumption rise by approximately 5%.

Détails

  • Titre original : A study of the transient characteristics of a self-regulating Joule-Thomson cryocooler.
  • Identifiant de la fiche : 1998-1424
  • Langues : Anglais
  • Source : Cryogenics - vol. 36 - n. 12
  • Date d'édition : 12/1996

Liens


Voir d'autres articles du même numéro (7)
Voir la source