Étude des performances de régénérateurs magnétiques actifs à double couche pour différents taux de remplissage dans un réfrigérateur magnétique à température ambiante.
Performance study of dual-layer active magnetic regenerators with different filling ratios in the room temperature magnetic refrigerator.
Résumé
Magnetic refrigeration technology is a solid-state cooling technology based on the magnetocaloric effect and possesses significant potential to replace vapor compression cooling technology. However, current magnetic refrigeration systems remain less competitive compared to vapor compression systems in terms of both cooling power density and energy efficiency. Employing a layered regenerator with magnetocaloric materials of different Curie temperatures is one of the promising strategies to improve the erformance of magnetic refrigeration systems. Four regenerators composed of a packed bed of 0.36 mm - 0.60 mm Gd and Gd94Er6 spheres were constructed in this paper. The filling ratios were 1:0, 8:2, 6:4, and 4:6 (Gd: Gd94Er6) respectively. Based on the previous magnetic refrigerator, the performance of four regenerators was evaluated for different operating conditions, which based on the temperature span with zero thermal load, cooling capacity, magnet power consumption, and COP. Experimental results indicate that the regenerator with a filling ratio of 6:4 exhibited optimal temperature span performance under all tested conditions. When operated at 1 Hz frequency, 0.6 utilization factor, and 30 ◦C hot-side temperature, it achieved a maximum temperature span of 22.7 K with zero thermal load. The magnet power consumption decreases as the filling ratio of Gd94Er6 increases. In consideration of COP values, single-layer Gd regenerator and those with filling ratios of 8:2 and 6:4 perform similarly at a 5 K temperature span, but the regenerator with a 6:4 filling ratio outperforms at spans over 15 K.
Documents disponibles
Format PDF
Pages : 12 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance study of dual-layer active magnetic regenerators with different filling ratios in the room temperature magnetic refrigerator.
- Identifiant de la fiche : 30034292
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 176
- Date d'édition : 08/2025
- DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2025.54.003
Liens
Voir d'autres articles du même numéro (30)
Voir la source
Indexation
- Thèmes : N/A
- Mots-clés : N/A