Document IIF
Étude des performances transitoires d’un système de déshumidification de l’air par déshydratant liquide à membrane à plaques refroidie par l’intérieur.
Transient performance study of an internally-cooled plate membrane liquid desiccant air dehumidification system.
Auteurs : YANG Y., YAN J., ZHOU X., XIAO L., HUANG S. M.
Type d'article : Article de la RIF
Résumé
An internally-cooled plate membrane liquid desiccant air dehumidification system has been adopted for air dehumidification due to its excellent ability of removing moisture. In this study, a dynamic model for the novel system is built up by coupling the model of each component. Based on the experimental data and the steady-state model, the dynamic model is validated to prove its accuracy. The transient performances of the system in a typical summer day are investigated. It is found that the operation process of the system during the daytime includes the start-up period and the stable running period. Owing to the rapid change of system parameters, the performances of the system during the start-up period are studied in detail. The results show that the temperatures of the solution in the solution tanks vary rapidly after starting up because of the low thermal inertia. Increasing cooling water flow rate or reducing cooling water temperature can improve the SDP of the system. The initial solution concentration and the volume of solution in the tank have a great effect on the start-up time, while the initial solution temperature has little influences.
Documents disponibles
Format PDF
Pages : 87-100
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Transient performance study of an internally-cooled plate membrane liquid desiccant air dehumidification system.
- Identifiant de la fiche : 30029113
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Date d'édition : 11/2021
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2021.08.006
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (95)
Voir la source
Indexation
-
Enhancing membrane-based air dehumidification t...
- Auteurs : FIX A., BRAUN J., WARSINGER D.
- Date : 10/07/2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Consideration of transient response and energy ...
- Auteurs : JALALZADEH-AZAR A. A.
- Date : 24/06/2000
- Langues : Anglais
- Source : ASHRAE Transactions. 2000 ASHRAE Annual Meeting, Minneapolis, Minnesota + CD-ROM.
Voir la fiche
-
Mathematical modelling and simulation analysis ...
- Auteurs : GUO Y., AL-JUBAINAWI A., MA Z.
- Date : 11/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 107
- Formats : PDF
Voir la fiche
-
On the application of a membrane air-liquid con...
- Auteurs : ISETTI C., NANNEI E., et al.
- Date : 05/1997
- Langues : Anglais
- Source : Energy Build. - vol. 25 - n. 3
Voir la fiche
-
Performance testing of a cross-flow membrane-ba...
- Auteurs : BAI H., ZHU J., CHEN Z., et al.
- Date : 05/06/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 119