Document IIF
Étude et comparaison numériques de la performance énergétique et de la destruction d'exergie des systèmes de déshumidification profonde en cascade avec un taux de déshumidification supérieur à 95 %.
Numerical investigation and comparison on energy performance and exergy destruction of cascading deep dehumidification systems with dehumidification amount exceeding 95%.
Résumé
Liquid desiccant and desiccant wheel systems are feasible approaches for the dehumidification process in modern buildings. Some specialized buildings and industrial fields have the demand for deep dehumidification process to produce supply air with low dew point temperature below 0 °C. In this study, the numerical investigation has been conducted to evaluate the energy and exergy performance of multiple cascading deep dehumidification systems assisted with liquid desiccant and desiccant wheel under a great dehumidification gradient. To process the air from 21 g/kg to 1 g/kg, the results indicate that the cascading liquid desiccant and desiccant wheel deep dehumidification system (LD-DW system) driven by two stages of heat pump exhibits the lowest demand of power consumption compared with the conventional dehumidification systems. It also shows less exergy loss and significantly higher exergy efficiency than other systems. The effects of influencing parameters on the dehumidification performance are also evaluated. The LD-DW system can effectively match the air state with the proper treatment dehumidification process, thus achieving a superior coefficient of system performance (COPsys) of 3.70, and it is an energy and exergy efficient method for advancing the deep dehumidification process.
Documents disponibles
Format PDF
Pages : 233-246
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Numerical investigation and comparison on energy performance and exergy destruction of cascading deep dehumidification systems with dehumidification amount exceeding 95%.
- Identifiant de la fiche : 30032054
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 155
- Date d'édition : 11/2023
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2023.08.015
Liens
Voir d'autres articles du même numéro (32)
Voir la source
-
Cycle simulation of the desiccant cooling syste...
- Auteurs : LEE D. Y., LEE J. W., KANG B. H.
- Date : 04/12/2002
- Langues : Anglais
- Source : Green breeze from Asia: frontiers of refrigerants, heat transfer and system.. ACRA-2002. Proceedings of the Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Performance analyses of an advanced heat pump d...
- Auteurs : LIU M., TU R., CHEN X., WU Z., ZHU J., YANG X.
- Date : 09/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 141
- Formats : PDF
Voir la fiche
-
Performance de déshumidification d'un système d...
- Auteurs : HORIBE A., TAKAKI S., INABA H., et al.
- Date : 2008
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 25 - n. 4
Voir la fiche
-
Sorptionsregenerator: Hauptbaustein des SGK-Kli...
- Auteurs : FRANZKE U.
- Date : 12/1999
- Langues : Allemand
- Source : KI Luft Kältetech. - n. 12
Voir la fiche
-
Effect of design and operating conditions on pe...
- Auteurs : TSUTSUI K., YAMAGUCHI S., SAITO K., et al.
- Date : 18/09/2008
- Langues : Anglais
- Source : HVAC Energy Efficiency Best Practice Conference
- Formats : PDF
Voir la fiche