Étude expérimentale d'un cryorefroidisseur Joule-Thomson à mélange de frigorigènes utilisant un compresseur à spirale pour conditionneur d'air commercial.
Experimental study of a mixed refrigerant Joule-Thomson cryocooler using a commercial air-conditioning scroll compressor.
Résumé
Mixed refrigerant Joule–Thomson (MR J–T) cryocoolers have been used to create cryogenic temperatures and are simple, efficient, cheap, and durable. However, compressors for MR J–T cryocoolers still require optimization. As the MR J–T cryocooler uses a commercial scroll compressor developed for air-conditioning systems, compressor overheating due to the use of less optimized refrigerants may not be negligible, and could cause compressor malfunction due to burn-out of scroll tip seals. Therefore, in the present study, the authors propose procedures to optimize compressor operation to avoid the overheating issue when the MR J–T cryocooler is used with a commercial oil lubricated scroll compressor, and the present experimental results obtained for a MR J–T cryocooler. A single stage 1.49 kW (2 HP) scroll compressor designed for R22 utilizing a mixture of nitrogen and hydrocarbons was used in the present study. As was expected, compressor overheating and irreversible high temperatures at a compressor discharge port were found at the beginning of compressor operation, which is critical, and hence, the authors used a water injection cooling system for the compressor to alleviate temperature overshooting. In addition, a portion of refrigerant in the high-pressure stream was by-passed into the compressor suction port. This allowed an adequate compression ratio, prevented excessive temperature increases at the compressor discharge, and eventually enabled the MR J–T cryocooler to operate stably at 121 K. The study shows that commercial oil lubricated scroll compressors can be used for MR J–T cryocooling systems if care is exercised to avoid compressor overheating.
Détails
- Titre original : Experimental study of a mixed refrigerant Joule-Thomson cryocooler using a commercial air-conditioning scroll compressor.
- Identifiant de la fiche : 30007651
- Langues : Anglais
- Source : Cryogenics - vol. 55-56
- Date d'édition : 05/2013
- DOI : http://dx.doi.org/10.1016/j.cryogenics.2013.02.001
Liens
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
-
The research and development of cryogenic mixed...
- Auteurs : LUO E., GONG M., ZHOU Y., et al.
- Date : 19/09/1999
- Langues : Anglais
- Source : 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
Voir la fiche
-
Studies on the performance of a small reciproca...
- Auteurs : LAKSHMI NARASIMHAN N., VENKATARATHNAM G.
- Date : 12/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 8
- Formats : PDF
Voir la fiche
-
Design and development of a high reliability, o...
- Auteurs : MESSAROS M. C., VERSTRAETE J. L.
- Date : 19/07/1994
- Langues : Anglais
- Source : Proceedings of the 1994 International Compressor Engineering Conference at Purdue.
Voir la fiche
-
Effect of mixture composition and hardware on t...
- Auteurs : LAKSHMI NARASIMHAN N., VENKATARATHNAM G.
- Date : 08/2011
- Langues : Anglais
- Source : Cryogenics - vol. 51 - n. 8
Voir la fiche
-
Refrigeration Linde-Hampson machine at 90K oper...
- Auteurs : DALAKOV P., KLIER J., ROZHENTSEV A.
- Date : 08/05/2019
- Langues : Anglais
- Source : Cryogenics 2019. Proceedings of the 15th IIR International Conference: Prague, Czech Republic, April 8-11, 2019.
- Formats : PDF
Voir la fiche