Document IIF
Étude expérimentale de l’ébullition en écoulement d’ammoniac dans un faisceau de tubes verticaux : Partie 4 - Analyse comparative
Experimental study of ammonia flow boiling in a vertical tube bundle: Part 4 – Comparative analysis
Auteurs : ABBAS A., AYUB Z., ISMAIL T., AYUB A., KHAN T. S., LI W., RIBATSKI G.
Type d'article : Article de la RIF
Résumé
This paper is the last leg of the previous three papers of the same series with experimental study carried on a vertical shell and tube heat exchanger comprising of seven dimpled enhanced tubes. Three different tube configurations were tested. (1) bare tube (2) with full length solid PVC nonconductive round rod insert (12.7 mm diameter) and (3) 33% cut insert. For the same flow, tubes with rods developed annular flow within the annular portion between the tube and the rod. Source of heat was hot ethylene glycol/water solution flowing on the shell side. Saturation temperature of ammonia was -20 °C ≤ ≤ -2 °C, heat flux range 5 kW m−2 ≤ ≤ 45 kW m−2 and mass flow rate of 0.008 and 0.015 kg s−1. Tests were conducted for each mass flow rate at four saturation temperature. Two-phase heat transfer coefficient increased with saturation temperature and heat flux for all cases with initial increase and then a drop at the onset of partial dry out. The tube with 33% cut rod exhibited better overall performance. Results were also compared with plate type evaporator data.
Documents disponibles
Format PDF
Pages : 141-152
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental study of ammonia flow boiling in a vertical tube bundle: Part 4 – Comparative analysis
- Identifiant de la fiche : 30029535
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 137
- Date d'édition : 05/2022
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.01.030
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
- Voir aussi : Experimental study of ammonia flow boiling in a vertical tube bundle: Part 1 – Enhanced dimple tube.
Experimental study of ammonia flow boiling in a vertical tube bundle: Part 2 – Enhanced dimple tube with full length solid round PVC nonconductive rod.
Experimental study of ammonia flow boiling in a vertical tube bundle: Part 3 – Enhanced dimple tube with 2/3rd height solid round PVC nonconductive rod.
Voir d'autres articles du même numéro (23)
Voir la source
-
Effect of micro-fin tube geometry parameters on...
- Auteurs : KEDZIERSKI M. A., LIN L., HAN K.
- Date : 01/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 157
- Formats : PDF
Voir la fiche
-
Entropy generation and sensitivity analysis of ...
- Auteurs : CAO Y., ABDOUS M. A., GHAZANFARI HOLAGH S. , SHAFIEE M., HASHEMIAN M.
- Date : 10/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 130
- Formats : PDF
Voir la fiche
-
New experimental data of CO2 flow boiling in mi...
- Auteurs : WU X., ZHU Y., TANG Y.
- Date : 11/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 59
- Formats : PDF
Voir la fiche
-
Simulation study on the performance of a vapor-...
- Auteurs : FAN C., YAN G., XIONG T., YU J.
- Date : 02/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 122
- Formats : PDF
Voir la fiche
-
Zastosowanie metody minimalizacji generacji ent...
- Auteurs : LASKOWSKI R., TOMCZAK P., JAWORSKI M.
- Date : 10/2015
- Langues : Polonais
- Source : Chlodnictwo - vol. 50 - n. 10-11
Voir la fiche