Résumé
Active chilled beam system, which gains popularity recently in Europe and North America, is known to be not only energy-efficient but also advantageous to uniform indoor environment quality. The objective of this study is to evaluate the performance of active chilled beam system in terms of air diffusion in the conditioned room. To compare the air diffusion performance with other systems, the evaluation was conducted using a full-scale test bed, where conventional CAV system, underfloor air distribution system, and active chilled beam system can be applied selectively. A 2-axis traverse system was utilized to measure the air temperature and air velocity in the entire space of the conditioned room. The air diffusion performance was evaluated using the three indices: ADPI to evaluate the uniform thermal comfort, vertical temperature difference to evaluate air stratification, and DR(draught rate) to evaluate the discomfort due to cold draft. The result shows that active chilled beam system is successful in providing the uniform indoor thermal environment with less supply air flow rate.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental study on the thermal uniformity of a room with an active chilled beam system.
- Identifiant de la fiche : 30010007
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Mesure; Air; Performance; Poutre froide; Distribution d'air; Diffusion
-
Methods of testing chilled beams.
- Auteurs : ASHRAE
- Date : 2015
- Langues : Anglais
Voir la fiche
-
Impact de l'utilisation de gaines horizontales ...
- Auteurs : INOUYE U., SHIBUYA E., INOUE M.
- Date : 05/2003
- Langues : Japonais
- Source : SHASE - vol. 77 - n. 5
Voir la fiche
-
Performance of chilled beam with radial swirl j...
- Auteurs : BERTHEUSSEN B., MUSTAKALLIO P., MELIKOV A., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Flow pattern and thermal comfort in office envi...
- Auteurs : KOSKELA H., HÄGGBLOM H., KOSONEN R., et al.
- Date : 08/2012
- Langues : Anglais
- Source : HVAC&R Research - vol. 18 - n. 4
Voir la fiche
-
Chilled beams and UFAD: an energy-efficient team.
- Auteurs : STRAPP P.
- Date : 05/2012
- Langues : Anglais
- Source : HPAC Engineering - vol. 84 - n. 5
Voir la fiche