ETUDE EXPERIMENTALE DE LA CONDENSATION DE MELANGES DE FRIGORIGENE ET D'HUILE. 2. RESULTATS POUR LE R12 ET LE R22 A LA SURFACE EXTERIEURE DE TUBES LISSES HORIZONTAUX SIMPLES OU MULTIPLES.

EXPERIMENTAL STUDY ON CONDENSATION OF REFRIGERANT-OIL MIXTURES. 2. RESULTS OF R12 AND R22 ON THE EXTERNAL SURFACE OF SINGLE AND MULTIPLE HORIZONTAL PLAIN TUBES.

Résumé

ON PRESENTE LES RESULTATS POUR LE R12 ET LE R22. 518 ESSAIS SONT ETUDIES, DONT 343 AVEC LE R12 ET 175 AVEC LE R22. L'HUILE UTILISEE DANS L'ETUDE EST A BASE D'ALKYLBENZENE. LA VAPEUR DE FRIGORIGENE, AVEC OU SANS PRESENCE D'HUILE, SE CONDENSAIT A LA SURFACE EXTERIEURE DE TUBES LISSES HORIZONTAUX SIMPLES OU MULTIPLES. ON A TROUVE QUE LE COEFFICIENT DE LA PELLICULE EN CONDENSATION POUR LES TUBES SIMPLES ET LES TUBES MULTIPLES ETAIT D'AUTANT PLUS FAIBLE QUE LE RAPPORT DES DEBITS-MASSES D'HUILE OU FRIGORIGENE ETAIT PLUS ELEVE. ON DONNE DES EQUATIONS EMPIRIQUES ET ON LES RECOMMANDE POUR LA CONCEPTION PRATIQUE DES CONDENSEURS A R12 ET A R22.

Détails

  • Titre original : EXPERIMENTAL STUDY ON CONDENSATION OF REFRIGERANT-OIL MIXTURES. 2. RESULTS OF R12 AND R22 ON THE EXTERNAL SURFACE OF SINGLE AND MULTIPLE HORIZONTAL PLAIN TUBES.
  • Identifiant de la fiche : 1986-2205
  • Langues : Anglais
  • Date d'édition : 1985
  • Source : Source : ASHRAE Trans.
    vol. 91; n. 2A; 229-237; 8 fig.; 4 ref.