Document IIF

Étude expérimentale des caractéristiques du bruit de l'écoulement diphasique du R410A à travers le détendeur électronique d'un climatiseur multi-split.

Experimental investigation on two-phase flow noise characteristics of R410A through electronic expansion valve of multi-split air conditioner.

Auteurs : ZHOU S., ZHANG F., DING G.

Type d'article : Article de la RIF

Résumé

The refrigerant flowing through an electronic expansion valve (EEV) of a multi-split air conditioner is usually in two-phase state which may generate more severe flow noise than that in sub-cooled state. The purpose of this paper is to experimentally investigate the influences of the two-phase R410A operation conditions on the flow noise characteristics in the EEV, including listening sense forms, frequency distributions and sound pressure levels (SPLs). The experimental conditions cover the refrigerant mass flow rate ranging from 30 to 90 kg h–1 and the refrigerant quality ranging from 0.02 to 0.4. The results show that low mass flow rate facilitates the reduction of noise frequency, and the peak noise frequency was reduced by up to 32% as the mass flow rate decreased. Low refrigerant quality helps to reduce the SPL of flow noise, and the average SPL decreased by 6 dB as the refrigerant quality decreased. The guidance of inlet flow pattern by transforming the churn flow to the annular flow helps to simultaneously reduce the noise frequency and SPL, and the peak noise frequency as well as the averaged SPL decreased by 47% and 4 dB, respectively. Moreover, the hissing noise and the gurgling noise are the only two kinds of listening sense forms of flow noise detected in the present experiment, and the peak frequency and the average SPL of hissing noise are both higher than those of gurgling noise.

Documents disponibles

Format PDF

Pages : 327-340

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental investigation on two-phase flow noise characteristics of R410A through electronic expansion valve of multi-split air conditioner.
  • Identifiant de la fiche : 30030912
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 146
  • Date d'édition : 02/2023
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.11.011

Liens


Voir d'autres articles du même numéro (41)
Voir la source