Résumé
In hot and humid regions, removal of moisture from the air represents a considerable portion of the air conditioning load. Conventionally, air conditioning systems have to lower the air temperature below its dew point to accomplish dehumidification. Desiccant air conditioners offer a solution to meet the humidity and temperature requirements of buildings via decoupling latent and sensible loads. In this work, the performance of a new polymer desiccant material is investigated experimentally. This desiccant material can be regenerated using a low temperature heat source. The effect of the process air stream’s temperature and humidity, the effect of the regeneration temperature, and the effect of the desiccant wheel’s rotational speed are investigated. ARI-humid conditions are used as a baseline and the moisture mass balance is maintained within 5%, based on ASHRAE 139-2007 standard. The results are presented in terms of the moisture removal rate, sensible effectiveness and latent coefficient of performance.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation of a desiccant wheel cycle.
- Identifiant de la fiche : 30008089
- Langues : Anglais
- Source : 4th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Date d'édition : 17/06/2013
Liens
- Voir les traductions : Investigación experimental del ciclo de una rueda desecante
Voir d'autres communications du même compte rendu (69)
Voir le compte rendu de la conférence
-
Investigación experimental del ciclo de una rue...
- Auteurs : LEE H., CAO T., HWANG Y., et al.
- Date : 05/2014
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - n. 469
- Formats : PDF
Voir la fiche
-
Characterization of desiccant wheels with alter...
- Auteurs : WHITE S. D., GOLDSWORTHY M., REECE R., et al.
- Date : 12/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
Voir la fiche
-
Experimental analysis on the performances of a ...
- Auteurs : ANGRISANI G., MINICHIELLO F., ROSELLI C., et al.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Measurements of effectiveness in a silica gel r...
- Auteurs : NETI S., WOLFE E. I.
- Date : 03/2000
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 20 - n. 4
Voir la fiche
-
Design of divided condensers for desiccant whee...
- Auteurs : LING J., HWANG Y., AUTE V., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche