Etude expérimentale du transfert de masse en convection laminaire forcée et de la chute de pression dans des microcanaux.

Experimental study of laminar forced convective mass transfer and pressure drop in microtubes.

Auteurs : SARA O. N., ERGU Ö. B., ARZUTUG M. E., et al.

Type d'article : Article

Résumé

The investigation of laminar convective mass transfer and friction factor was performed experimentally for the circular tubes with the diameter of 0.20 mm and the L/d values in the range of 100-500 for a Reynolds number range of 40-1400. The pressure drop experiments were conducted with distilled water, and the mass transfer experiments were carried out with an electrochemical solution by using the electrochemical limiting diffusion current technique. The friction factor results showed good agreement with the classical Poiseuille flow theory, while Sherwood numbers are smaller than those obtained by conventional correlations. [Reprinted with permission from Elsevier. Copyright, 2009].

Détails

  • Titre original : Experimental study of laminar forced convective mass transfer and pressure drop in microtubes.
  • Identifiant de la fiche : 2010-0739
  • Langues : Anglais
  • Source : International Journal of thermal Sciences - vol. 48 - n. 10
  • Date d'édition : 10/2009
  • DOI : http://dx.doi.org/10.1016/j.ijthermalsci.2009.01.021

Liens


Voir d'autres articles du même numéro (1)
Voir la source