Document IIF

Etude expérimentale sur la performance d'un tube vortex de type Ranque-Hilsch en cascade chaud et analyse de l'exergie.

Experimental investigation of performance of hot cascade type Ranque-Hilsch vortex tube and exergy analysis

Auteurs : DINCER K., YILMAZ Y., BERBER A., et al.

Type d'article : Article, Article de la RIF

Résumé

In this study, three Ranque-Hilsch vortex tubes were used, which have 9 mm inside diameter and length/diameter ratio was 15. Their performances were examined as one of the classical RHVT and other was hot cascade type RHVT. Performance analysis was according to temperature difference between the hot outlet and the inlet (?Thot.). The ?Thot values of hot cascade type Ranque-Hilsch vortex tubes were greater than the ?Thot values of classical RHVT, which were determined experimentally. The total inlet exergy, total outlet exergy, total lost exergy and exergy efficiency of hot stream were investigated by using experimental data. In both the classical RHVT and hot cascade type RHVT, it was found that as fraction of cold flow increases the total lost exergy decreases. It was also found that, the hot cascade type RHVT more exergy efficiency of hot outlet than the classical RHVT. Excess ?Thot value of hot cascade type Ranque-Hilsch vortex tube causes the excess exergy efficiency of hot outlet.

Documents disponibles

Format PDF

Pages : 1117-1124

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental investigation of performance of hot cascade type Ranque-Hilsch vortex tube and exergy analysis
  • Identifiant de la fiche : 30000568
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 4
  • Date d'édition : 06/2011

Liens


Voir d'autres articles du même numéro (35)
Voir la source