Résumé
The experiments on heat transfer, flow resistance, and fouling characteristics of normal tubes or twisted tubes in a condenser were conducted. The normal tube size was phi 25 x 25. the twisted tubes were made of the normal tube with the same size, and the screw pitch was 12, and 180 mm, respectively. The results show that flow resistance coefficient of the twisted tube is about 1.75-2 times that of the normal tube, and it increases with the decrease of screw pitch. The heat transfer coefficient of the twisted tube is about 1.2-2.3 times that of the normal tube at the clean condition and 1.8-2.1 times at the fouling condition. The heat resistance of fouling decreases when Re increases, but it decreases much more for the twisted tube. When Re= 3000, the values of fouling heat resistance for both tubes are very close. As Re>6000, the fouling heat resistance of the twisted tube is about 0.16-0.42 times that of the normal tube. On the basis of the experimental results, the optimum range of Re for the fouling twisted tube was obtained.
Documents disponibles
Format PDF
Pages : 47-50
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 2008-1258
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 28 - n. 118
- Date d'édition : 12/2007
Liens
Voir d'autres articles du même numéro (5)
Voir la source
-
Experimental study of the effect of twisted-tap...
- Auteurs : MOGAJI T. S., KANIZAWA F. T., BANDARRA FILHO E. P., et al.
- Date : 03/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 2
- Formats : PDF
Voir la fiche
-
Numerical investigation on condensation heat tr...
- Auteurs : WEN J., GU X., WANG S., et al.
- Date : 01/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Formats : PDF
Voir la fiche
-
Transfert de chaleur et chute de pression du R1...
- Auteurs : ONAKA Y., HOSSAIN M. A., MIYARA A.
- Date : 2011
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 28 - n. 4
Voir la fiche
-
Effect of tube diameter on boiling heat transfe...
- Auteurs : JIGE D., SAGAWA K., INOUE N.
- Date : 04/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 76
- Formats : PDF
Voir la fiche
-
Experimental study on condensation heat transfe...
- Auteurs : WANG L., DANG C., HIHARA E.
- Date : 08/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 5
- Formats : PDF
Voir la fiche