Etude expérimentale sur les caloducs cryogéniques à oscillation.

Experimental investigation of cryogenic oscillating heat pipes.

Auteurs : JIAO A. J., MA H. B., CRITSER J. K.

Type d'article : Article

Résumé

A novel cryogenic heat pipe, oscillating heat pipe (OHP), which consists of an 4 x 18.5 cm evaporator, a 6 x 18.5 cm condenser, and 10 cm length of adiabatic section, has been developed and experimental characterization conducted. Experimental results show that the maximum heat transport capability of the OHP reached 380 W with average temperature difference of 49°C between the evaporator and condenser when the cryogenic OHP was charged with liquid nitrogen at 48% (v/v) and operated in a horizontal direction. The thermal resistance decreased from 0.256 to 0.112 while the heat load increased from 22.5 to 321.8 W. When the OHP was operated at a steady state and an incremental heat load was added to it, the OHP operation changed from a steady state to an unsteady state until a new steady state was reached. This process can be divided into three regions: (I) unsteady state; (II) transient state; and (III) new steady state. In the steady state, the amplitude of temperature change in the evaporator is smaller than that of the condenser while the temperature response keeps the same frequency both in the evaporator and the condenser. The experimental results also showed that the amplitude of temperature difference between the evaporator and the condenser decreased when the heat load increased. [Reprinted with permission from Elsevier. Copyright, 2009].

Détails

  • Titre original : Experimental investigation of cryogenic oscillating heat pipes.
  • Identifiant de la fiche : 2009-1962
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 52 - n. 15-16
  • Date d'édition : 07/2009
  • DOI : http://dx.doi.org/10.1016/j.ijheatmasstransfer.2009.03.013

Liens


Voir d'autres articles du même numéro (6)
Voir la source